Prysmian

FRIC 3Cx300mm2 6/10kV

Prysmian FRIC 3Cx300mm2 6/10kV — 300 mm² cross-section. The supplied category identifies the equipment as 10 kV), and it is normally installed routed through cable trays, penetrations and equipment terminations between switchboards, machinery, sensors or communication equipment. In that listed role, its primary purpose is to carry electrical power, control signals or data between shipboard systems. Power, control, communication and fire-resistant cables differ in conductor size, insulation, screening and fire performance, so substitution must follow the approved cable specification. The model designation identifies the listed configuration, but no additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

cross section mm2 300
voltage class 6/10kV
cores 3
material Cu
insulation EPR
fire rating IEC60332-1
halogen free False

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Mechanical damage, crushing or excessive bending damages insulation and causes earth faults or conductor failure
Loose or corroded terminations cause heating, voltage drop, intermittent control signals or communication loss
Water ingress at glands or damaged sheaths reduces insulation resistance and causes intermittent faults
Heat, oil or chemical exposure degrades insulation and produces cracking or discoloration
Poor screening, grounding or separation on signal cables causes electrical noise and unstable data

Service & Maintenance

Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using approved test methods appropriate to the circuit. Maintain fire-stopping and segregation at penetrations. Refer to the cable and equipment documentation for the exact figure for test voltages, bend radii and termination requirements.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry suitable glands, lugs, ferrules, heat-shrink or approved jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Equipment Model #85370 · ✓ still in production