TKF/TKD

S7 Marine 3Cx185mm2 0.6/1kV

TKF/TKD S7 Marine 3Cx185mm2 0.6/1kV is a shipboard unit in the Cable & Wiring group, classified in the source as Power Cable (0.6/1 kV). It is normally installed in cable trays, transits, machinery spaces, switchboard rooms, deck routes or control/communication networks according to voltage and service. Its primary duty is to carry electrical power, control signals, instrumentation or communications between shipboard equipment while maintaining the required marine environmental and fire-performance properties. In service it interfaces with terminal boxes, switchboards, motors, sensors, automation cabinets, cable glands, transits and protective devices. The source record states 185 mm² cross-section for this exact variant; this information is retained unchanged and distinguishes it from neighboring entries in the same product family. For exact limits, settings, test values and approved maintenance criteria, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

cross section mm2 185
voltage class 0.6/1kV
cores 3
material Cu
insulation XLPE
fire rating IEC60332-1
halogen free False

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks

Service & Maintenance

Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Equipment Model #84935 · ✓ still in production