Riello UPS Marine Sentinel Rack 10kVA 400V is identified in the source list as a marine uninterruptible power supply. It is installed in a dedicated battery or electrical room with ventilation, cooling, fire protection and isolation arrangements required by the vessel design. Its purpose is to store or condition electrical energy and maintain supply to selected propulsion, automation, navigation or emergency consumers according to the system type. The source record provides no additional model-specific operating figure beyond the listed designation and category. Battery modules or UPS power electronics, control units, protection, cooling, monitoring and bypass or contactor arrangements form an integrated electrical system. The exact model designation and source-listed energy, power or voltage distinguish rating and architecture from neighboring units; refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

capacity kwh 1.5
chemistry VRLA
cycle life 300
c rate 1.0
class approval DNV GL

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Battery cell or module imbalance caused by aging, temperature difference or internal deterioration, resulting in warnings, reduced autonomy or protective limitation
Cooling or ventilation failure caused by fan, pump, filter or control faults, resulting in elevated temperature and derating or shutdown
Power-module, inverter or rectifier failure caused by electrical stress or component aging, resulting in loss of protected output or a UPS alarm
Battery-management, sensor or communication failure caused by wiring, electronics or network faults, resulting in missing data, alarms or protective shutdown
Insulation, contactor or connection deterioration caused by moisture, contamination or electrical stress, resulting in ground-fault alarms, overheating or loss of availability

Service & Maintenance

Review alarms, battery or DC-link condition, temperatures, load, bypass status and insulation monitoring without overriding protective functions. Inspect cooling, ventilation, cable connections, racks, contactors, fuses and fire-protection interfaces for abnormal condition. Verify emergency shutdown, bypass or isolation functions using approved procedures. Keep battery and electrical spaces clean, dry and within specified environmental conditions. Preserve event logs and configuration before approved module or software replacement. Refer to the manufacturer documentation for the exact figure for cell limits, autonomy, transfer criteria and electrical tests.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep approved fuses, contactors, sensors, cooling fans or pumps, filters, power modules and manufacturer-recommended control electronics. Battery modules or cells must only be replaced with approved compatible units using the required safety procedure. Preserve configuration and commissioning tools for critical systems.
Equipment Model #84570 · ✓ still in production