"> Corvus Energy Orca ESS 500 LFP
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 1 verified suppliers & service companies for Corvus Energy in the Maritime Network Find suppliers →
Corvus Energy

Orca ESS 500 LFP

Corvus Energy Orca ESS 500 LFP — Battery & UPS Systems. The supplied category identifies the equipment as Lithium-Ion Battery System (ESS), and it is normally installed in a dedicated battery room, battery container or protected electrical space with charging, monitoring and ventilation or cooling appropriate to the installed technology. In that listed role, its primary purpose is to store electrical energy for emergency supply, ride-through, hybrid propulsion support or other shipboard power functions. Lithium-ion ESS and conventional marine UPS arrangements differ in energy scale, battery chemistry and protection, but both depend on reliable monitoring, charging, isolation and thermal control. The model designation identifies the listed configuration, but no additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Corvus Energy Orca ESS 500 LFP

Components & Design

Component data being added…

Technical Data

capacity kwh 500
chemistry LFP
cycle life 6000
c rate 1.0
class approval DNV GL

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Cell or battery ageing causes reduced capacity, voltage imbalance or low-runtime alarms
Cooling or ventilation failure causes rising battery temperature, thermal alarms or derating
Battery-management, charger, inverter or communication faults cause loss of availability or automatic isolation
Insulation deterioration or DC earth faults cause insulation alarms and can block connection to the electrical system
Loose high-current terminals or degraded interconnections cause local heating, voltage drop or intermittent supply

Service & Maintenance

Review battery or BMS alarms, voltage and temperature trends, insulation monitoring, charging, cooling and emergency isolation. Inspect enclosures, terminals and cable joints for heat damage, corrosion or movement. Verify charger, inverter and backup functions under the approved vessel procedure. Refer to the manufacturer documentation for the exact figure for voltage, state-of-charge, temperature and replacement limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry approved fuses, contactors, charger or inverter modules where supported, temperature or voltage sensors, cooling components and battery modules or replacement batteries according to the vessel support plan.
Equipment Model #84424 · ✓ still in production