"> Qingdao Marine QD-INC-100
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 171 verified suppliers & service companies for Qingdao Marine in the Maritime Network Find suppliers →
Qingdao Marine

QD-INC-100

Qingdao Marine QD-INC-100 is identified in the source list as a marine incinerator. It is normally installed in a dedicated machinery-space or incinerator room with combustion-air, exhaust, fuel, sludge and waste-handling arrangements. Its purpose is to burn approved shipboard waste streams under controlled conditions in accordance with the vessel's approved operating procedures and applicable regulations. The existing database record provides no additional model-specific operating figure beyond the listed designation and category. The category associates the equipment with IMO MEPC.244, while the exact burner, chamber, sludge system and control arrangement depend on the model. The exact model designation identifies the approved incinerator configuration; rated capacity, permitted waste types and operating limits must be taken from the manufacturer documentation and approval certificate.

Components & Design

Component data being added…

Technical Data

capacity kw 100
waste type all
imo compliant True
burning rate kg h 4.545454545454546

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Ignition or flame failure caused by fuel, burner, electrode or air-supply problems, resulting in failed starts or burner trips
Poor combustion caused by wet waste, excessive feed, burner fouling or inadequate air, resulting in smoke, unstable temperature or incomplete burn
Refractory damage caused by thermal cycling, impact or overheating, resulting in visible cracking, hot spots or exposed casing areas
Sludge burner or feed-system blockage caused by high solids, poor heating or contamination, resulting in loss of sludge-burning capability
Temperature, draft or interlock faults caused by sensor, fan or control problems, resulting in alarms, unstable furnace conditions or shutdown

Service & Maintenance

Inspect burners, ignition devices, combustion-air fans, waste-loading mechanisms, sludge lines and refractory condition. Remove ash and deposits using approved procedures and inspect door seals and casing for hot spots or leakage. Function-test temperature controls, flame safeguards, interlocks and emergency stops after maintenance. Keep prohibited materials out of the incinerator and follow the vessel's approved garbage and sludge procedures. Investigate persistent smoke or incomplete combustion before further operation. Refer to the manufacturer documentation and the approved certificate for exact operating temperatures, waste restrictions and maintenance criteria.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep burner nozzles or atomizing components as applicable, ignition parts, flame sensors, door seals, gaskets, selected refractory repair materials and control or temperature-sensor spares recommended by the manufacturer. Sludge-pump or feed-system consumables should match the installed arrangement. Confirm exact parts from the model and certificate documentation.
Equipment Model #74190 · ✓ still in production