TeamTec OG 400

TeamTec TeamTec OG 400 — Incinerator, marine waste incineration; source metadata also lists power 45.0 kW, capacity 400 kg/h. The supplied category identifies the equipment as Marine Incinerator, and it is normally installed in a dedicated machinery or incinerator space with combustion-air, exhaust, sludge or waste-feed and fuel connections. In that listed role, its primary purpose is to reduce approved combustible shipboard waste and sludge in a controlled combustion chamber. Compared with ordinary burning equipment, a marine incinerator operates with dedicated safety interlocks, burner controls and environmental operating restrictions. Within the supplied list, this variant is distinguished from neighbouring entries by its model designation and the explicitly listed power and capacity; further hardware differences are not stated in the source. No additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

45.0 kW
Power
400 kg/h
Capacity

Components & Design

Component data being added…

Technical Data

incinerator type marine waste incinerator
capacity kg h 400
imo mepc MEPC.244(66)
fuel MDO

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Burner fouling, ignition failure or poor atomization causes flame failure, smoke or inability to maintain combustion
Refractory cracking or erosion causes shell hot spots and visible internal damage
Combustion-air fan or damper faults cause poor draft, smoke or unstable chamber temperature
Sludge or waste-feed blockage causes irregular burning or feed-system failure
Temperature-sensor, flame-monitor or control-interlock faults cause nuisance trips or prevent a safe burn sequence

Service & Maintenance

Inspect refractory, chamber surfaces, burners, fans, dampers, waste and sludge feed, exhaust path and safety interlocks. Check for ash accumulation, leakage and abnormal shell hot spots. Verify flame-failure and temperature protections under the approved procedure. Refer to manufacturer and statutory documentation for the exact figure for operating and emissions limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry burner nozzles, ignition parts, flame detectors, temperature sensors, fan and damper service parts, approved refractory repair material, seals and control relays.
Equipment Model #68700 · ✓ still in production