Central Cooler (Plate Type) · Heat Exchangers

Class-certified type (DNV register) · technical data sheet not yet verified​‌​​​​‌‍‍‌‌​‌​‌‍‍​‍‌

Alfa Laval M10-MFM-90P gasketed plate-and-frame heat exchanger from the M-line (marine central cooling). Plate count 10-250, max flow rate 55 m3/h, design pressure 16 bar, max temperature 110 C. M-line is the workhorse industrial gasketed PHE — widely used for marine LT/HT cooling and engine cooling.

Specifications

Technical data.

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Heat Exchanger TypeAlfa Laval Gasketed Plate Heat Exchangers (GPHE)
Inspection

Inspector Detail

Common issues

  • Gasket degradation over time causing seepage between plates, especially after thermal cycling
  • Plate fouling (scaling, biological growth, or corrosion product) on the seawater side reducing heat transfer
  • Cross-contamination between the two fluid circuits if a plate develops a pinhole or crack
  • Corrosion or erosion of plates in the seawater circuit, particularly at flow entry points
  • Tightening bolt corrosion making disassembly for cleaning difficult
  • Reduced cooling performance from increased fouling resistance not being caught until temperatures trend upward

Inspection checklist

  • Check LT/HT cooling water temperature differential against the design/reference values for signs of fouling
  • Inspect plate pack for external leakage at the gasket line, particularly after any pressure or thermal transient
  • Open and inspect plates for scaling, pitting, or gasket wear at the scheduled interval
  • Check tightening bolts and plate pack dimension against the manufacturer's assembly measurement
  • Verify pressure drop across the unit has not increased significantly versus baseline, indicating fouling
  • Inspect for any sign of cross-contamination between circuits (oil in cooling water or vice versa)

Service intervals

Performance check (temperature differential, pressure drop)monthly or per the vessel's PMS rounds
Full opening, cleaning, and gasket inspectiontypically every 12-24 months depending on fouling rate and water quality - confirm against Alfa Laval's M-line service schedule
Gasket renewalat each full opening where gaskets show hardening, compression set, or damage

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Typical wear limits

Plate pack tightening dimensionmust be reassembled to the compressed length stamped on the frame or stated in Alfa Laval's manual for this plate count - do not estimate, confirm against the unit's own data plate
Pressure drop increase indicating fouling requiring cleaningcommonly flagged once differential pressure rises on the order of 20-30% above the clean baseline - confirm the vessel's own acceptance criterion

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Gasket set matched to the M10-MFM-90P plate pattern
  • Plate set (spares for plates found pitted or cracked at overhaul)
  • Tightening bolt and nut set

Safety

  • Depressurise and isolate both circuits before opening the plate pack
  • Allow the unit to cool before opening if operating on the HT circuit to avoid scald injury
  • Follow the manufacturer's specified tightening sequence and dimension when reassembling to avoid gasket blow-out under pressure

Class survey

Plate heat exchangers in engine cooling service are typically part of Continuous Survey Machinery for essential cooling systems. Surveyors expect evidence of periodic opening/cleaning and gasket condition records, and may request pressure test results after reassembly for units in critical cooling duty.

Need this part?

Request a quote for this model.

Free of charge — send us your request for Alfa Laval equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Central Cooler (Plate Type).

Other models of the same equipment type, Alfa Laval first.

By manufacturer Alfa LavalWärtsiläAPVGEASondexAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Alfa Laval models More like Alfa Laval M10-MFM-90P
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Alfa Laval M10-MFM-90P — a part, a service call, a second opinion. Are you Alfa Laval? Claim this brand page.

Service engineer? Write the day report for this M10-MFM-90P in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.