Fire Resisting Material Type: “EGGER Schichtstoff (EGGER laminate); EGGER Schichtstoff mit farbigem Kern (EGGER laminate coloured core); EGGER Schichtstoff lackierfaehig (EGGER painting grade)”; decorative veneers (EGGER Schichtstoff (EGGER laminate); EGGER Schichtstoff mit farbigem Kern (EGGER laminate coloured core) and EGGER Schichtstoff lackierfaehig (EGGER painting gade).)
Fire Resisting Material Type: “EGGER Schichtstoff (EGGER laminate); EGGER Schichtstoff mit farbigem Kern (EGGER laminate coloured core); EGGER Schichtstoff lackierfaehig (EGGER painting grade)”; decorative veneers (EGGER Schichtstoff (EGGER laminate); EGGER Schichtstoff mit farbigem Kern (EGGER laminate coloured core) and EGGER Schichtstoff lackierfaehig (EGGER painting gade).). Category: Surface materials and floor coverings with low flame-spread characteristics: decorative veneers.. Module: D. Manufacturer: Egger Kunststoffe GmbH & Co. KG.
Inspector Detail
▸
Common issues
- Delamination or bubbling of the laminate face from the substrate, often from moisture at joints
- Edge/joint sealant failure allowing water to track behind panels
- Unauthorized substitution with non-certified laminate during repairs, invalidating the fire division rating
- Surface scratching/gouging exposing substrate in high-traffic areas
- Colour/finish mismatch after partial panel replacement
- Fixing or adhesive failure at panel-to-bulkhead attachment points
- Discoloration from prolonged UV exposure near windows/deckheads
Inspection checklist
- Verify the fitted panel type/reference against the DNV/MED type approval certificate on file
- Check for delamination, bubbling, or lifting at seams and edges
- Inspect fixing points and adhesive bond integrity
- Confirm fire division markings (A-class/B-class) are legible and correct
- Check that cable/pipe penetrations through the panelling retain their approved fire-stopping
- Verify no unapproved laminate has been used in any repair
- Inspect for physical damage exposing the core material
- Confirm surface finish (paintable grade where fitted) has not been compromised in a way that affects fire performance
Service intervals
| Visual condition inspection | at each accommodation/fire round, or annually |
| Adhesion/edge sealant check | annually |
| Fire-stopping penetration check | at each fire round or annual survey |
| Type approval reference verification | at each class renewal survey |
Critical spares
- Matching certified laminate sheet stock (same reference/type as approved) for panel replacement
- Approved edge sealant/trim compatible with the fire division rating
- Fire-rated core board matching the certified assembly
- Approved adhesive that maintains the panel's fire performance
- Fixing hardware (clips/rails) matching the original installation system
Safety
- Panel failure or an improper repair can compromise A/B-class fire division integrity
- Adhesives/solvents used in repair may be flammable - hot work restrictions apply nearby
- Damaged panelling can expose combustible substrate
Class survey
Surveyors check that the fitted laminate matches the referenced MED/DNV type approval (certificate number on file) and that repairs have not substituted non-certified material, since a fire division's rating depends on the whole certified assembly, not just the visible surface.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →