Hi-Fog open type spray heads. Models 4S 1MC 8MB 1000, 5S 1MC 8MB 1000, and 5S 1MC 8MC 1000.
Hi-Fog open type spray heads. Models 4S 1MC 8MB 1000, 5S 1MC 8MB 1000, and 5S 1MC 8MC 1000.. WATER MIST FIRE EXTINGUISHING SYSTEM. Local Application Water Mist System
Inspector Detail
▸
Common issues
- Spray nozzle blockage from scale, debris or corrosion affecting the mist pattern
- Accumulator/pump unit pressure loss or pump failure
- Section valve failing to open or close on demand (manual or actuated)
- High-pressure piping corrosion or leakage at joints
- Poor water quality/filtration causing nozzle fouling
- Loss of power or control signal to the release/detection panel
Inspection checklist
- Check accumulator/pump unit pressure and standby readiness
- Visual check of nozzles for corrosion, blockage or physical damage
- Function test of section valves, manual and remote release
- Check high-pressure piping and fittings for leaks or corrosion
- Test the detection and release panel/alarm function
- Check water supply/filter unit condition
- Confirm local application zone coverage matches the protected equipment layout
- Review the last system function/flow test records
Service intervals
| Visual nozzle/piping inspection | per PMS, typically quarterly |
| System function/flow test | annually, per SOLAS/maker requirement |
| Pump/accumulator unit service | per maker schedule, typically annually |
| Filter element renewal | per maker recommendation or on pressure drop |
Typical wear limits
| Nozzle orifice condition | renew on visible corrosion or blockage that cannot be cleared by flushing - no generic figure applies |
| High-pressure hose/piping | renew per maker service life or on visible corrosion/leakage - confirm against the maker manual |
Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.
Critical spares
- Spray nozzle sets, correct type per protected zone
- Section valve actuator/solenoid
- Filter elements for the water supply unit
- Pressure switches/transmitters for pump control
- Seals/gaskets for high-pressure piping joints
Safety
- High-pressure water mist system - do not work on pressurised piping without isolation
- Accidental discharge risk during testing - follow lockout procedure and warn personnel in the space
- Electrical hazard at the pump/control panel during servicing
- Slip hazard from test discharge water in the machinery space
Class survey
Deviation from order data: this record is filed under 'CO2 Fixed System', but the product description identifies it as a Marioff Hi-Fog OPEN TYPE local-application WATER MIST system - this entry addresses the actual water mist system, not a CO2 fixed gas system. Local application water mist protection for machinery spaces is surveyed under SOLAS II-2 with annual function tests and periodic (often multi-year) high-pressure piping/accumulator inspection; class typically requires nozzle inspection and system flow test records.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →