OceanSphereENGINES
Library› Deck› Ship Structure & Outfitting› Flame Arrester› Braunschweiger Flammenfilter GmbH Protego® BE/HR-E-DN-IIB3
Braunschweiger Flammenfilter GmbH

Protego® BE/HR-E-DN-IIB3

Flame Arrester · Ship Structure & Outfitting

Class-certified type (DNV register) · technical data sheet not yet verified​​⁠‍‍‌​⁠⁠​‍‍​​‌​‌​‌⁠

Protego® BE/HR-E-DN-IIB3 by Braunschweiger Flammenfilter GmbH. DNV TA certificate TAP00000C9.

Inspection

Inspector Detail

Common issues

  • Corrosion or fouling of the flame-arrester element reducing free flow area
  • Blockage or icing of the element in cold-climate or high-humidity cargo trades
  • Sticking or seized pallets on the pressure/vacuum relief function, if combined with a P/V valve
  • Gasket or seal degradation at flange connections leading to venting-system leaks
  • Mechanical damage to the housing or flame screen following an over-pressurisation event
  • Salt or particulate build-up on the element increasing back-pressure in the venting line

Inspection checklist

  • Visually inspect the flame-arrester element for corrosion, deformation or blockage
  • Check the free flow area of the element against the manufacturer's cleaning/renewal criteria
  • Test the P/V function pallets for free movement and correct set pressure, if fitted
  • Inspect housing and flange gaskets for leakage
  • Confirm the DNV type-approval certificate and nameplate data match the installed unit
  • Check drainage of condensate from the housing where applicable
  • Verify correct orientation and support of the unit on the vent line

Service intervals

Element cleaning/inspectiontypically every 12 months, more frequently in high-fouling cargo trades or per class-approved maintenance scheme
P/V function set-pressure testtypically annually, aligned with the tank venting system survey
Full element renewalon condition, when the element can no longer be cleaned to the manufacturer's clear-area criteria

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Typical wear limits

Element free-flow arearenewal is normally based on the manufacturer's stated minimum clear-area percentage rather than a fixed dimension - use the type-approval documentation for this specific unit, not a generic figure
P/V set pressuremust be verified against the nameplate/type-approval value for certificate TAP00000C9, not a generic setting

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Flame-arrester element (crimped-ribbon insert)
  • P/V pallet and seat set (if combined unit)
  • Housing gasket set

Safety

  • A degraded element can fail to stop flame propagation into the cargo tank - treat maintenance as safety-critical, not routine
  • Work at the vent riser may involve a potentially flammable gas atmosphere - follow hazardous space entry procedures
  • Incorrect reassembly (wrong element orientation, damaged gasket) can defeat the flame-arresting function without being visually obvious

Class survey

DNV type approval (TAP00000C9) ties the installed unit to a specific certified configuration; surveyors check that the nameplate matches the certificate and that the element has been maintained per the manufacturer's instructions - fitting a non-approved replacement element invalidates the certification.

Estimated lifetime: Not meaningfully expressed in running hours; service life is governed by element condition (corrosion, blockage) and is normally assessed at each annual tank venting system survey rather than by a fixed hour or year figure.

Classification

DNV type approval

Listed in the DNV Approval Finder at the time we recorded it. The certificate is issued by DNV, not by us; check its current status at DNV.

CertificateTAP00000C9
Open the certificate at DNV
Need this part?

Request a quote for this model.

Free of charge — send us your request for Braunschweiger Flammenfilter GmbH equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Flame Arrester.

Other models of the same equipment type, Braunschweiger Flammenfilter GmbH first.

By manufacturer EmersonProsavePres-Vac EngineeringKaeser Kompressoren SEBraunschweiger Flammenfilter GmbHScanjet MarineAXCES BVBBM Acoustic India Pvt. Ltd.Discom B.V.Dürr LimitedFDC Co., Ltd.Miratech Prior Lake, Inc.Niikura KogyoPROTEGOSe-Won Ind. Co., Ltd.All manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner More like Protego® BE/HR-E-DN-IIB3
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Braunschweiger Flammenfilter GmbH Protego® BE/HR-E-DN-IIB3 — a part, a service call, a second opinion. Are you Braunschweiger Flammenfilter GmbH? Claim this brand page.

Service engineer? Write the day report for this Protego® BE/HR-E-DN-IIB3 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.