FL220NF-N-B15A, FL240NF-N-B15A, LEB407NF-N-B15A, LEB807NF-N-B15A, LEB125NF-N-B15A, LEB225NF-N-B15A

FL220NF-N-B15A, FL240NF-N-B15A, LEB407NF-N-B15A, LEB807NF-N-B15A, LEB125NF-N-B15A, LEB225NF-N-B15A by DAEYANG ELECTRIC CO., LTD.. DNV TA certificate TAF00000CZ.

Inspector Detail

Common issues

  • Gasket/seal degradation on watertight fixtures allowing moisture ingress
  • Corrosion of the housing or terminals in exposed or damp locations
  • LED driver or fluorescent ballast failure
  • Diffuser/lens yellowing or cracking
  • Terminal corrosion causing intermittent operation
  • Cable gland deterioration allowing water ingress at the entry point
  • Lumen depreciation over service life (LED types)

Inspection checklist

  • Check housing and gasket condition for damage or UV degradation
  • Verify watertight closure and cable gland integrity
  • Check terminals for corrosion and confirm earthing continuity
  • Function test (operation, flicker, brightness)
  • Check diffuser/lens for cracking or heavy yellowing
  • Confirm the fixture's certification marking matches its installed zone (e.g. explosion-protected units in hazardous areas)
  • Check mounting/fixing security against vibration
  • Inspect for moisture inside the housing when opened for maintenance

Service intervals

Routine function check at planned maintenance rounds
Gasket/seal inspection and renewal per maker's schedule or when degradation is observed
LED driver / ballast replacement on failure, no fixed running-hours interval commonly published
Insulation resistance / earth continuity check periodically per the vessel's electrical maintenance plan

Critical spares

  • Gasket/seal kit
  • Diffuser/lens cover
  • LED driver or ballast/starter
  • Cable gland
  • Lamp/tube (fluorescent types)

Safety

  • Isolate and lock out the circuit before opening any fixture
  • Explosion-protected fixtures must only be opened, repaired or have covers refitted per their certification - unauthorised parts or an incorrectly refitted gasket can void the explosion-protection rating
  • Risk of electric shock from damaged wiring or corroded terminals
  • Working at height when servicing overhead fixtures

Class survey

Marine lighting fixtures in hazardous or classified spaces must retain their explosion-protection/type approval marking; electrical survey typically checks fixture condition, gasket integrity on watertight/explosion-protected types, and that emergency/escape route lighting is functional and correctly distributed per SOLAS requirements.

Estimated lifetime: LED marine lighting fixtures of this class are typically rated for tens of thousands of hours (commonly on the order of 30,000-50,000 hours to L70 lumen maintenance) before significant light output decline; fluorescent variants have a shorter tube/ballast service life measured in a few thousand to around ten thousand hours - confirm against the specific fixture's datasheet.

Components & Design

Component data being added…

Technical Data

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

DNV type approval

Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.

Certificate
TAF00000CZ
Approved as
Class B Recesses for Light Fittings, Ventilation Units and similar · Fire Safety
Certificate holder
DAEYANG ELECTRIC CO., LTD. (Republic of Korea)
Valid until
2026-11-23
Open the certificate at DNV →
Equipment Model #58122 · ✓ still in production