OceanSphereENGINES
Library› Engine Room› Industrial Valves› Valve Actuator› AMOT UK HOLDINGS LIMITED EB100, EB200
AMOT UK HOLDINGS LIMITED

EB100, EB200

Valve Actuator · Industrial Valves

Class-certified type (DNV register) · technical data sheet not yet verified​​⁠‌⁠‍​​⁠‌⁠⁠‌⁠​‌‍​​⁠

EB100, EB200 by AMOT UK HOLDINGS LIMITED. DNV TA certificate TAA000010U.

Inspection

Inspector Detail

Common issues

  • Antenna/measuring horn fouling from cargo vapour condensation or product build-up
  • Signal loss or erratic reading from a still-pipe obstruction or misalignment
  • Servo/electronics fault in the transmitter head causing loss of level signal to the cargo control room
  • Calibration drift between the radar reading and manual ullage/sounding
  • Power supply or intrinsically-safe barrier fault causing loss of reading
  • Condensation or moisture ingress into the transmitter housing affecting reliability

Inspection checklist

  • Cross-check the radar level reading against a manual ullage/sounding tape at a stable condition
  • Inspect the antenna/horn for cargo residue or corrosion build-up
  • Check the still-pipe for obstructions, holes or misalignment affecting the signal path
  • Verify transmitter housing seals and cable glands are intact for hazardous-area integrity
  • Confirm high-level and overfill alarm setpoints trigger correctly during test
  • Check the power supply/barrier and the communication link to the cargo control/monitoring system
  • Inspect earthing/bonding of the gauge housing per hazardous area requirements
  • Review calibration/zero-span records against the maker's procedure

Service intervals

Cross-check against manual soundingat each cargo operation, per company procedure
Full calibration checkannually, or per maker/class recommendation
Antenna/still-pipe cleaningat drydock, or sooner if fouling is evident from reading discrepancies
Overfill/high-level alarm function testbefore cargo operations and at periodical survey, per class and terminal requirements

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Typical wear limits

Reading accuracy vs. manual soundingcommonly expected within a small tolerance, on the order of a few millimetres to about 1 cm depending on tank height - confirm the exact accuracy class against the DNV type-approval certificate rather than treating this as a fixed figure

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Transmitter head/electronics module - confirm the exact AMOT part number with an authorised service agent, none assumed here
  • Cable gland/seal kit for the hazardous-area housing
  • Remote display/indicator unit in the cargo control room
  • Antenna extension/horn assembly

Safety

  • Installed in a hazardous cargo tank area - any repair or gland work must preserve the intrinsic safety/explosion-proof certification; do not substitute non-approved parts
  • Loss of an accurate level reading during loading is an overfill risk - have a backup sounding method ready before working on the gauge
  • Static/bonding continuity must be verified after any housing work

Class survey

Cargo tank level and overfill alarm systems are safety-critical under SOLAS/IBC Code requirements for tankers. Class surveys require function/accuracy verification of level gauging and of the independent high-level/overfill alarm, with the DNV type-approval certificate (TAA000010U) confirming the design meets the applicable performance standard.

Estimated lifetime: Radar level transmitters are continuously energised rather than hour-counted; typical service life before major electronics renewal is on the order of 10-15 years - confirm against AMOT's product documentation for the EB100/EB200.

Classification

DNV type approval

Listed in the DNV Approval Finder at the time we recorded it. The certificate is issued by DNV, not by us; check its current status at DNV.

CertificateTAA000010U
Open the certificate at DNV
Need this part?

Request a quote for this model.

Free of charge — send us your request for AMOT UK HOLDINGS LIMITED equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Valve Actuator.

Other models of the same equipment type.

By manufacturer EmersonHanla IMSEltorqueRotorkAUMAFikeEBRO Armaturen Gebr. BröerSwagelokRotork Gears BVSamsonSharpeSomas InstrumentFisherBettisNutorkAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner More like EB100, EB200
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this AMOT UK HOLDINGS LIMITED EB100, EB200 — a part, a service call, a second opinion. Are you AMOT UK HOLDINGS LIMITED? Claim this brand page.

Service engineer? Write the day report for this EB100, EB200 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.