Auto-Maskin AS

DCU 408E, DCU 410, DCU 410E, RP 410E, RP 420E, RP 480i, RIO 410, RPS, SDU 404, SDU 410, SDU 420, Marine Pro - 400 Series

DCU 408E, DCU 410, DCU 410E, RP 410E, RP 420E, RP 480i, RIO 410, RPS, SDU 404, SDU 410, SDU 420, Marine Pro - 400 Series by Auto-Maskin AS. DNV TA certificate TAA00000Z6.

Inspector Detail

Common issues

  • Radar antenna or stillwell fouling from cargo vapour condensation or wax/paraffin buildup, reducing signal return
  • Stillwell/bypass chamber blockage giving false or frozen level readings
  • Signal cable or gland corrosion at deck penetrations causing intermittent readings
  • Firmware mismatch between sensor unit and display/deck control unit after a partial system update
  • Loss of communication on the tank gauging bus after a power supply or UPS fault
  • Calibration drift after tank cleaning or coating work carried out near the sensor

Inspection checklist

  • Verify displayed level against an independent means (sounding pipe or portable gauge) before cargo operations
  • Check antenna/stillwell for deposits, condensation or physical damage during tank inspection
  • Inspect cable glands and junction boxes at deck penetrations for corrosion and water ingress
  • Confirm high-level and high-high alarm setpoints match the cargo plan and are tested
  • Check power supply/UPS backup status and battery condition
  • Review the system event log for repeated communication faults or sensor dropouts
  • Confirm software/firmware version consistency across sensor and display units

Service intervals

Antenna/stillwell visual check each cargo operation or at least every 3 months
Independent level verification against a reference gauge before each cargo transfer
Cable gland and junction box inspection annually
Firmware/software version check at planned maintenance and after any unit replacement

Critical spares

  • Antenna/sensor unit (model-specific)
  • Signal/display unit
  • Cable glands and terminal kit
  • UPS battery for the gauging system
  • Fuses and surge protection modules
  • Junction box seals

Safety

  • A false low or high reading during loading/discharge can lead to tank overfill or dry-running of cargo pumps
  • Work on the stillwell/antenna often requires tank entry or hot-work precautions - follow the vessel's permit-to-work system
  • Electrical work on the sensor circuit in a hazardous area zone requires a gas-free certificate and intrinsically safe tools

Class survey

Cargo tank level and overfill alarm systems on tankers fall under the vessel's cargo system survey requirements; class typically expects functional testing of level and high-level alarms, verification against an independent gauging method, and calibration records retained onboard. Log any sensor replacement and re-verify readings before the next cargo operation.

Components & Design

Component data being added…

Technical Data

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #56045 · ✓ still in production