LS Cable & System Ltd (Donghae Plant)

FRA-MPICI/ MPIOI/ MPICI(C)/ MPIOI(C)/ MPICIE/ MPIOIE/ MPICIE(C)/ MPIOIE(C)/TTPIOI(C)/ TTPICI(C)/ TTPIOI(I)/ TTPICI(I)/ TTPIOI(I/C)/ TTPICI(I/C)

FRA-MPICI/ MPIOI/ MPICI(C)/ MPIOI(C)/ MPICIE/ MPIOIE/ MPICIE(C)/ MPIOIE(C)/TTPIOI(C)/ TTPICI(C)/ TTPIOI(I)/ TTPICI(I)/ TTPIOI(I/C)/ TTPICI(I/C) by LS Cable & System Ltd (Donghae Plant). DNV TA certificate TAE00004K5.

Inspector Detail

Common issues

  • Insulation resistance degradation from moisture ingress at glands or terminations
  • Sheath abrasion or chafe at cable transits and bends
  • UV degradation of outer sheath on exposed deck runs
  • Armor corrosion in wet, salt-laden spaces
  • Overheating or insulation breakdown from overloading or poor derating in bundled runs
  • Termination lug looseness causing localized hot spots

Inspection checklist

  • Insulation resistance (megger) test at scheduled intervals
  • Visual inspection of cable runs for chafe, mechanical damage, or sheath cracking
  • Gland and penetration seal condition check (watertight/gastight integrity)
  • Cable support and cleating condition check - no sagging or chafe
  • Termination and lug tightness check, thermal imaging where practical
  • Armor continuity and earthing check

Service intervals

Insulation resistance testing per PMS, commonly annually or per class requirement for critical circuits
Visual inspection of exposed runs annually or at each survey
Thermal imaging of major terminations/switchboards condition-based or per company policy

Typical wear limits

Insulation resistance investigate or renew the run once IR falls clearly below general guidance for the voltage class - confirm the exact class/maker threshold for the specific circuit

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Cable by type and size, cut to length as needed (no fixed part number)
  • Cable glands and penetration seals
  • Termination lugs/ferrules

Safety

  • Fire-spread risk if the wrong cable type is substituted for a fire-rated circuit - never substitute types by space classification
  • Electric shock hazard from damaged insulation - isolate before working on a run
  • Armor must be properly earthed to avoid stray currents and shock hazard

Class survey

Class checks that the installed cable's type approval (TAE00004K5) matches installation drawings, that fire-rated (FR/FRA) types are used in required spaces such as essential and emergency circuits, and reviews insulation resistance test records at periodic survey.

Components & Design

Component data being added…

Technical Data

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

DNV type approval

Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.

Certificate
TAE00004K5
Approved as
Low Voltage Cable · Electrical Equipment and Systems
Certificate holder
LS Cable & System Ltd (Donghae Plant) (Republic of Korea)
Valid until
2027-10-24
Open the certificate at DNV →
Equipment Model #55278 · ✓ still in production