SG CS Performance Monitoring System
SG CS Performance Monitoring System by Neuver Maritime AS. DNV TA certificate TAA00003S1.
Inspector Detail
▸
Common issues
- Radar signal loss or erratic readings from foam, turbulence, or vapor condensation on the antenna
- Antenna or still-pipe fouling from cargo residue or wax buildup affecting accuracy
- Communication link failure between the tank unit and the cargo control room display
- Calibration drift over time versus manual dip/ullage readings
- Power supply or intrinsically-safe barrier fault causing loss of reading
- Water ingress into the tank-top junction box affecting signal integrity
Inspection checklist
- Cross-check radar reading against manual ullage/dip measurement
- Inspect antenna horn/still-pipe for residue buildup or damage where accessible
- Verify junction box and cable gland sealing at the tank top
- Check intrinsically-safe barrier and power supply status
- Confirm high-level and high-high alarm setpoints against the cargo plan
- Review historical trend data for drift or erratic behaviour
- Test the communication link to the cargo control room / IAS
- Verify still-pipe venting, where fitted, is not obstructed
Service intervals
| Cross-check against manual gauging | each cargo operation, minimum monthly |
| Calibration verification | annually or per maker recommendation |
| Antenna/still-pipe cleaning inspection | at dry-docking or when accuracy drift is noted |
| High-level alarm function test | before each cargo loading, per ISGOTT/SOLAS practice |
Typical wear limits
| Level reading accuracy vs. manual dip | commonly within about 2-5 mm depending on system class - confirm against the maker's stated accuracy and the cargo's custody transfer requirement |
Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.
Critical spares
- Antenna/radar sensor unit of matching type
- Junction box seal and cable gland set
- Intrinsically-safe barrier module
- Display/interface unit fuses
- Communication cable
Safety
- False level readings can lead to tank overfill - a major fire/explosion and pollution hazard
- Work on tank-top electrical connections requires intrinsically-safe procedures and gas-free verification
- High-level alarm bypass or failure removes a critical overfill safeguard - never disable without compensating measures
- Static discharge risk when opening tank fittings on tanks carrying flammable cargo
Class survey
Class and cargo surveys typically check that the high-level alarm is independently tested from the primary gauging system, that calibration records exist, and that the installation matches the tank's approved custody-transfer/overfill protection arrangement.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →DNV type approval
Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.
- Certificate
- TAA00003S1
- Approved as
- Control and Monitoring System · Instrumentation and Automation
- Certificate holder
- Neuver Maritime AS (Norway)
- Valid until
- 2027-11-13