T25DXY Type Continuous Class B-0 Ceiling
T25DXY Type Continuous Class B-0 Ceiling by Huanan Building Materials (Shenzhen) Co., Ltd.. DNV TA certificate TAF00000NV.
Inspector Detail
▸
Common issues
- Panel joint sealant deterioration allowing a smoke/fire path at seams
- Corrosion of the support framework/hangers in humid or engine-room-adjacent spaces
- Panel delamination or core degradation from moisture ingress
- Damage from accidental impact during maintenance work above the deckhead
- Incorrect reinstatement after access panels are removed for cable/pipe work, breaking fire integrity
- Fixings loosening from vibration over time
Inspection checklist
- Visual check of panel joints and seams for gaps or damaged sealant
- Inspect support framework and hangers for corrosion or loose fixings
- Check for delamination, bulging, or moisture staining on panel faces
- Verify access panels/hatches close and seal correctly after maintenance access
- Confirm the panel system matches the approved fire division drawing for that space
- Check for unauthorised penetrations (added cables/pipes) without proper fire-stopping
Service intervals
| Visual inspection as part of fire round | at least annually, more often in wet or engine-adjacent spaces |
| Framework/hanger corrosion check | annually |
Typical wear limits
| Visible joint gap before resealing is needed | any gap breaking the continuous seal at panel joints should be treated as requiring repair, per the approved system's fitting instructions |
Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.
Critical spares
- Replacement panel sections of the same certified type
- Joint sealant/trim matching the approved system
- Support framework/hanger components
Safety
- Removing or damaging panels can compromise the fire/smoke division rating of the space
- Panels above deckheads may conceal cabling or piping - verify isolation before disturbing
- Cutting or drilling into panels for new penetrations without proper re-sealing afterward leaves the division uncertified
Class survey
Surveyors checking B-0 class divisions look for physical continuity of the panel and joint system against the approved fire division drawing, confirmation that the installed system matches its type approval, and that any penetrations (cables, pipes, ducts) are properly fire-stopped. This is a passive fire protection item rather than continuous survey machinery.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →DNV type approval
Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.
- Certificate
- TAF00000NV
- Approved as
- Horizontal Class B Division · Fire Safety
- Certificate holder
- Huanan Building Materials (Shenzhen) Co., Ltd. (China)
- Valid until
- 2028-01-15