Prysmian Group Finland Oy

LSM-HF 1,8/3 kV or TEMAR PHFX-A 1,8/3 kV

LSM-HF 1,8/3 kV or TEMAR PHFX-A 1,8/3 kV by Prysmian Group Finland Oy. DNV TA certificate TAE00000SC.

Inspector Detail

Common issues

  • Insulation thermal ageing at heavily loaded cable runs, especially near switchboards
  • Gland moisture ingress at deck and bulkhead penetrations
  • Mechanical damage sustained during cable pulling or later maintenance work nearby
  • Screen or armour corrosion in damp trunking or bilge-adjacent routes
  • Overheating at poorly torqued terminations rather than the cable itself
  • Rodent or mechanical chafe damage inside cable trunking on older vessels

Inspection checklist

  • Thermal check (by hand-held thermometer or thermal imaging where available) at terminations and lugs
  • Insulation resistance test on the run, logged and trended over time
  • Check termination and lug tightness/torque at switchboards and junction boxes
  • Visual inspection of the cable route for chafe, crushing, or exposed conductor
  • Check cable support spacing has not sagged or allowed chafe against structure
  • Confirm cable identification/tagging is legible and matches the single-line/cable schedule
  • Check earthing continuity of screen/armour where fitted

Service intervals

Insulation resistance test annually, per the vessel's planned maintenance system
Thermal check of terminations annually, or sooner on heavily loaded circuits
Visual route inspection annually
Termination torque check at major overhaul or when a termination is disturbed for any reason

Critical spares

  • Spare cable length of the correct rating and fire/halogen performance
  • Cable lugs and terminations matching conductor size
  • Heat-shrink termination and jointing kits
  • Cable glands rated for the installation location

Safety

  • Shock and arc-flash hazard at terminations carrying up to 1.8/3 kV - isolate and prove dead before working
  • Fire risk from insulation failure if the wrong cable type or a damaged run has gone unnoticed
  • Confined cable routes through trunking where access for inspection is limited

Class survey

Class checks that the DNV type-approved cable actually installed matches the approved cable schedule for this circuit, that halogen-free/low-smoke requirements for the space are met, and wants insulation resistance test records available at survey rather than a one-off check on the day.

Components & Design

Component data being added…

Technical Data

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

DNV type approval

Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.

Certificate
TAE00000SC
Approved as
Electric Power Cable · Electrical Equipment and Systems
Certificate holder
Prysmian Group Finland Oy (Finland)
Valid until
2030-06-30
Open the certificate at DNV →