PANELFA, S.L.

A/B light weight ceiling CB1502

A/B light weight ceiling CB1502 by PANELFA, S.L.. DNV MED certificate MEDB00006GA.

Inspector Detail

Common issues

  • Panel sagging or joint gaps opening where suspension grid spacing exceeds the approved maximum
  • Corrosion of steel suspension components in humid or exterior-adjacent spaces
  • Impact damage to panel core or facing from cargo/stores handling in accommodation alleyways
  • Loss of fire integrity where cable or duct penetrations were cut without approved fire-stopping
  • Discolouration or delamination of the facing sheet from prolonged moisture exposure (deckhead leaks)
  • Replacement panels installed that do not match the certified A/B class build-up

Inspection checklist

  • Visual check of panel joints, sag, and fixing security at accommodation deck surveys
  • Verify suspension grid and hangers match the approved system (spacing, fixing type)
  • Check cable/pipe penetrations for proper certified fire-stopping and sealant
  • Confirm panel markings/certificate reference (MEDB00006GA) are traceable on replacement stock
  • Inspect for water staining indicating deckhead leaks that could compromise the core
  • Check condition of any acoustic/thermal insulation behind panels where accessible

Service intervals

General condition check at periodic accommodation space surveys
Suspension grid fixings check at each dry-docking for corrosion or loosening

Critical spares

  • Replacement panel sections matching the certified core and facing build-up
  • Suspension grid components (hangers, rails, clips) matching the approved system
  • Edge trims, joint strips and fixings matching the certified installation

Safety

  • Fire class (A/B) depends on the complete certified system - do not substitute or modify components without approval, as this can invalidate the fire rating
  • Handle and store panels to avoid damaging the core, which is the primary fire/insulation barrier
  • Control dust when cutting or drilling panel cores per the manufacturer's material safety data

Class survey

Surveyor confirms the installed system matches the DNV MED Module B approval (cert. MEDB00006GA) for A/B class division, checks fire-stopping at penetrations, and looks for unauthorised alterations that could affect the certified fire rating.

Components & Design

Component data being added…

Technical Data

imo approved True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #40086 · ✓ still in production