Library› Safety & LSA› Fire Hoses & Nozzles› Fire Hose› Rapp Bomek AS H051S - Single Hinged (A60)
Rapp Bomek AS

H051S - Single Hinged (A60)

Fire Hose · Fire Hoses & Nozzles

Class-certified type (DNV register) · technical data sheet not yet verified

Rapp Bomek AS H051S is a single-hinged A60 fire-rated door and should not be treated as a fire hose. It is installed in an A-class fire division to provide personnel access while preserving the required fire integrity of the surrounding bulkhead or enclosure. The door leaf, frame, insulation, hinges, latch and approved hardware function as one tested assembly. A single-hinged arrangement is used where one clear opening is sufficient, in contrast with wider double-leaf fire-door designs. The A60 designation means that installation details, frame attachment, clearances and any vision panel or hardware option must remain within the approved configuration. Damage that still allows the door to open and close can nevertheless compromise its fire performance. The database category should be corrected so inspections focus on the door and passive fire boundary rather than on hose equipment.

Specifications

Technical data.

Every value below comes from the manufacturer datasheet or class-society record on file for this model.

IMO ApprovedYes
Related models

Also in Fire Hose.

Other models of the same equipment type, Rapp Bomek AS first.

Service

Service notes.

What our service work and the manufacturer documentation say about keeping this model running.

Service notes

Function-test opening, closing and latching and inspect the door leaf, frame, hinges, seals and hardware as part of the vessel's passive-fire-protection program. Verify that the door is not wedged open and that any approved self-closing or hold-open arrangement operates as intended for that installation. Check the identification plate and confirm that replacement hardware is approved for the H051S door system. Corrosion repairs must not reduce the door or frame section or disturb insulation without an approved repair method. Clearances, closing force, seal details and repair tolerances must be taken from Rapp Bomek documentation and the vessel's fire-control approval.

Inspection

Common failures & inspection points

Inspection

Inspector Detail

Common issues

  • Corrosion or seizure of the cabinet door hinges and latch mechanism, especially in weather-exposed locations
  • Damage to the A60 insulation core of the door from impact or improper closing
  • Missing or perished door gasket/seal, reducing the fire integrity of the A60 rating
  • Paint or corrosion buildup preventing the door from closing and latching fully
  • Hose, nozzle or valve missing or damaged inside the cabinet at inspection

Inspection checklist

  • Confirm cabinet door opens, closes and latches correctly, with the A60 seal intact
  • Visual check for corrosion, denting or coating damage on the door and frame
  • Check hose, nozzle and isolating valve are present and undamaged inside the cabinet
  • Verify fire hose station marking/signage is legible and correctly located per the fire control plan
  • Confirm certificate/model reference (MEDB00006ST) matches the installed equipment on class documentation
  • Function test the hydrant valve for free operation as part of fire main testing

Service intervals

Visual/function check of cabinet and doormonthly as part of fire-fighting equipment rounds
Hose pressure testper SOLAS/class requirement, typically every few years or on hose condition
Hinge/latch lubricationat routine maintenance rounds, using a lubricant compatible with fire safety equipment

Critical spares

  • Door gasket/seal set for the A60 door
  • Hinge and latch mechanism
  • Replacement fire hose matching the station's length and coupling type
  • Nozzle/spray-jet fitting
  • Hydrant valve spares (washers, seats)

Safety

  • A60 rating depends on the door, core and seal being intact - do not paint over or damage the gasket
  • Ensure the open cabinet door does not obstruct an escape route
  • Hose under pressure can whip if not properly secured - brief crew on safe deployment

Class survey

Surveyor checks fire hose stations against the fire control plan for location and marking, and A60 boundary integrity where fitted in a fire-rated division, and witnesses a hose/hydrant function test; the certificate (DNV MED Module B, cert. MEDB00006ST) is checked for validity.

Spares

Replacement Parts

Spare parts notes

Useful onboard spares include model-compatible hinge components, latch or handle parts, approved seals or gaskets, closer components where fitted and the correct fasteners or hardware items. On vessels with many identical Rapp Bomek doors, one complete critical hardware set can prevent prolonged impairment of a fire division. Do not install generic door hardware simply because it fits mechanically; fire-door approval depends on the tested assembly.

Classification

DNV type approval

Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.

CertificateMEDB00006ST
Open the certificate at DNV
Need this part?

Request a quote for this model.

Free of charge — we forward your request to qualified suppliers for Rapp Bomek AS equipment from our network of over 114,000 maritime companies.

Makers and authorised dealers rarely quote marine equipment without the vessel. With these details we usually come back with prices; without them we have to ask first, which costs a few days. If you cannot share the vessel, a photo of the equipment’s rating plate does the same job — send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
By manufacturer AFRISOWISKASwagelokEndress+HauserAlfa Laval S.p.A.MAN Energy SolutionsWärtsiläABB MarineAlfa LavalMacGregorNovenco MarineseimihanlaimsDESMICarrier MarineAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner More like H051S - Single Hinged (A60)
Would you like to know more?

One person answers within 24 hours on working days.

Tell us what you need for this Rapp Bomek AS H051S - Single Hinged (A60) — a part, a service call, a second opinion. Are you Rapp Bomek AS? Claim this brand page.

Service engineer? Write the day report for this H051S - Single Hinged (A60) in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Three things people ask first.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.