K-Load, Version 5.0
K-Load Version 5.0 is Kongsberg’s bridge integration system that aggregates data from radars, AIS, ECDIS, gyro‑compasses and other navigation sensors into a single, configurable display suite with built‑in redundancy.
Inspector Detail
▸
Common issues
- Software/firmware compatibility issues after partial system updates
- Sensor data dropout (GPS, gyro, AIS) from wiring/interface faults rather than the integration system itself
- Display/processing unit hardware faults (fan, power supply) from vibration or heat in bridge consoles
- Network/data bus (NMEA, LAN) communication faults causing intermittent sensor loss
- Alarm management configuration drift after updates or crew changes
- Backup/redundancy changeover not seamless if the UPS or redundant unit is not tested regularly
Inspection checklist
- Functional test of primary-to-backup system changeover
- Verification that all integrated sensor inputs (GPS, gyro, log, AIS, radar, echo sounder) are live and plausible
- Alarm management system function and audible/visual alarm test
- Software/firmware version check against the class-approved configuration
- UPS/backup power supply function and battery condition check
- Network cabling and connector inspection for corrosion/damage
- Chart/ECDIS data currency check where integrated
- BNWAS/watchkeeping interface test where integrated
Service intervals
| Software/firmware update review | per manufacturer release schedule, condition/requirement-based |
| UPS battery test | annually, with replacement typically every 3-5 years |
| Full system function test | annually or per class survey cycle |
| Sensor calibration check (gyro, log) | per individual sensor manufacturer's interval, typically annual |
Typical wear limits
| UPS battery service life | typically 3-5 years before capacity degrades below reliable backup duration - replace on age/capacity test rather than waiting for failure |
| Processing unit cooling fan | renew if noise/vibration increases, or at the manufacturer's recommended preventive interval, typically 3-5 years |
Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.
Critical spares
- Processing unit / operator station (long lead time)
- UPS batteries
- Network switches/interface units
- Display unit
Safety
- Over-reliance on the integrated display without independent cross-check of raw sensor data
- Loss of navigation situational awareness during a system update or changeover if not properly sequenced
- Electrical hazard at power supply/UPS units during servicing
Class survey
Integrated bridge/navigation systems are covered under SOLAS Ch. V navigation equipment carriage requirements. Class/flag checks that individually type-approved sensors remain type-approved, that the integration does not degrade required stand-alone functionality, and that backup/redundancy arrangements meet the applicable IBS/INS performance standard (e.g. IEC 61924-2). Software version and configuration records should be retained for survey.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Common failures & inspection points
Service & Maintenance
Annual inspection per SOLAS/Flag State. Software updates per manufacturer advisory. Sensor calibration quarterly. Backup system test monthly.