Messwertauflösung2 mm (0.08 in)
Maximale Messabweichung±0,2 %
Typische Messabweichung±4 mm (0.16 in) oder 0,2 % der Messdistanz*
Weightca. 4 (8.82) kg (lbs)
Max 2,5bar ABS.36psia
UNI Flansch 6"/DN150/150max 2,5bar abs./ 36psia
UNI Flansch DN200/200max 2,5bar abs./ 36 psia
UNI Flansch 4"/DN100/100max 2,5bar abs./ 36psia
8" 150lbs FF316L
Klemmenspannung maximal36 V
Stromaufnahme20 mA
Referenzbedingungen Temperatur+20 °C (68 °F)
Referenzbedingungen Druck1013 mbar abs. (15 psi abs.)
Referenzbedingungen Luftfeuchte50 %
Messwertauflösung FMU442 mm (0.08 in)
Messrate (2-Draht-Geräte)max. 0,4 Hz
Messabweichung FMU44± 4 mm (0.16 in) oder 0,2% der eingestellten Messdistanz (Leerabgleich)1
Gewicht kg (lbs)ca. 4 (8.82) kg (lbs)
ProduktstrukturFMU44
CertificationsNI Cl.I Div.2, Zone 0,1,2
Messratemax. 0,4 Hz
Messabweichung± 4 mm (0.16 in) oder 0,2% der eingestellten Messdistanz (Leerabgleich)
Montagebügel316 Ti (1.4571)
50 (2.0)50 (2.0)
100 (3.9)100 (3.9)
20 (0.8)20 (0.8)
35 (1.4)35 (1.4)
25 (1.0)25 (1.0)
75 (2.9)75 (2.9)
105 (4.1)105 (4.1)
22 (0.9)22 (0.9)
Maximale Reichweite in Flüssigkeiten120 m
Maximale Reichweite in Schüttgütern110 m
Blockdistanz0,5 m
Process connection8" 150lbs FF, 316L, max 2,5bar abs./36psia
Hilfsenergie; Ausgang2-Leiter; 4-20mA HART
Maximale Reichweite in Flüssigkeiten20 m
Maximale Reichweite in Schüttgütern10 m
Passend zu6" 150lbs / DN150 PN16 / 10K 150
Process connection8" 150lbs FF, 316L, max 2.5bar abs./36psia
Power supply; OutputB 2-wire; 4-20mA HART, D 2-wire; PROFIBUS PA, F 2-wire; FOUNDATION Fieldbus, G 4
SensorFMU44
Α11 °
Lmax20 m
Rmax1.93 m
Maximum range in liquids120 m
Maximum range in solids110 m
Blocking distance0.5 m
Max. range fluids20 m
Max. range bulk materials10 m
Blocking distance0.5m
Max. range liquids0.5 m
Dmin. 150 mm
Lapprox. 400 mm
Bd0.5 m
Maximum range in liquids20m
Maximum range in solids10m
Measuring error±4mm or 0.2% of set measuring distance (empty calibration)1
Sensor α11°
Nozzle diametermin. 150 mm
Max. nozzle lengthapprox. 400 mm
Operation1 w/o display, via communication, 2 4-line display VU331, Envelope curve display
Sd10 m
Ambient temperature-40 °C ... +80 °C
Storage temperature-40 °C ... +80 °C
Ingress protectionIP 68, NEMA 6P (24h at 1.83m under water surface)
Vibration resistance20…2000 Hz, 1 (m/s2)2/Hz; 3 x 100 min
Reaktionszeitmin. 3 s
Reaktionszeit (2-Draht-Geräte)min. 3 s
Schutzart (geöffnet)IP20, NEMA 1
Terminal voltage10 to 36 V
Temperature–40 to 80 °C (–40 to 176 °F)
Pressure0.7 to 2.5 bar (10.15 to 36.25 psi)
Maximum measuring rangeliquids 20 m (66 ft), bulk solids 10 m (33 ft)
Communication resistor250 Ω
Operating frequencyapprox. 30 kHz
Maximum sound pressure level143 dB
Distance of threshold value 110 dB2.7 m
Output signal4 to 20 mA with HART
Min. load for HART communication250 Ω
Fixed current for Multidrop mode4 mA
Start-up current11 mA
Power consumption51 to 800 mW
Wire cross-sections0.5 to 2.5 mm2 (20 ... 14 AWG)
Maximum length of non-insulated wires or stranded wire7 mm (0.28 in)
Cable glandM20×1.5 (cable diameter 6 to 10 mm (0.24 to 0.39 in)
HART ripple47 to 125 Hz: Uss = 200 mV (at 500 Ω)
HART noise500 Hz to 10 kHz: Ueff = 2.2 mV (at 500 Ω)
Measured value resolution2 mm (0.08 in)
Maximum measured error±0.2 % in relation to the maximum sensor span
Pulse frequency Two-wire version≤ 0.4 Hz
Nozzle length400 mm
Ambient temperature range–40 to +80 °C
Degree of protection (open)IP20, NEMA 1
Process temperature range–40 to +80 °C (–40 to +176 °F)
Process pressure range0.7 to 2.5 bar abs. (10.15 to 36.25 psi)
Maximum value for empty calibration20 000 mm
Minimum distance between reference point R of the sensor and 100 % level500 mm
Maximum value for full calibration19 500 mm
Minimum span E - A250 mm
Kommunikationswiderstand250
Arbeitsfrequenzca. 30 kHz
Maximaler Schalldruckpegel143 dB
Abstand vom Schwellenwert 110 dB2,7 m (8,9 ft)
Ausgangssignal4 … 20 mA mit HART
Min. Bürde für HART-Kommunikation250 Ω
Versorgungsspannung14 … 36 V
Leistungsaufnahme51 … 800 mW
Adernquerschnitt0,5 … 2,5 mm2 (20 ... 14 AWG)
KabelverschraubungM20×1,5
Welligkeit HART47 … 125 Hz: Uss = 200 mV (bei 500 Ω)
Rauschen HART500 Hz ... 10 kHz: Ueff = 2,2 mV (bei 500 Ω)
Minimale Werte: Zweidrahtausführung≥ 3 s
Messrate Zweidrahtausführung≤ 0,4 Hz
Maximale Stutzenlänge400 mm (15,7 in)
Umgebungstemperaturbereich–40 … +80 °C (–40 … +176 °F)
SchwingungsfestigkeitDIN EN 60068-2-64/IEC 68-2-64: 20 … 2 000 Hz, 1 (m/s2)2/Hz; 3 x 100 min
Prozesstemperaturbereich–40 … +80 °C (–40 … +176 °F)
Prozessdruckbereich0,7 … 2,5 bar abs. (10,15 ... 36,25 psi)
Weightca. 4 kg (8,82 lb)
Maximaler Wert für den Leerabgleich20 000 mm
Minimale Distanz zwischen Referenzpunkt R des Sensors und 100 % Füllstand500 mm
Maximaler Wert für den Vollabgleich19 500 mm
Minimale Spanne E - A250 mm
Weight kg (lbs)approx. 4 (8.82)