Maximum measuring range80 m (262 ft)
Temperature–40 to +200 °C (–40 to +392 °F)
Pressure–1 to +25 bar (–14.5 to +363 psi)
Accuracy±1 mm (±0.04 in)
CertificationsSIL2 nach IEC 61508
Current output 14.0 to 20.5 mA
NAMUR NE 433,8 … 20,5 mA
US mode3,9 … 20,8 mA
Current output 24 to 20 mA passive (optional)
Switching delayUser-programmable in the 0 to 100 s range, separate for switch-on point and swit
Load4 to 20 mA HART
R L max1065 W
U10.5 V
RLmax maximum load resistance23 mA
Power supply10.5 to 30 VDC Ex i
Ub10.5 V
HART loadMin. 250 Ω
Rated cross-section0.5 to 2.5 mm2 (20 to 13 AWG)
Protective earth or grounding of the cable shield> 1 mm2 (17 AWG)
External ground terminal0.5 to 4 mm2 (20 to 12 AWG)
Plastic gland⌀5 to 10 mm (0.2 to 0.38 in)
Nickel-plated brass gland⌀7 to 10.5 mm (0.28 to 0.41 in)
Stainless steel gland⌀7 to 12 mm (0.28 to 0.47 in)
Reference operating conditionsTemperature = +24 °C (+75 °F) ±5 °C (±9 °F)
Reflectormetal plate with diameter ≥ 1 m (40 in)
Measured value resolutionDead band according to DIN EN IEC 61298-2 / DIN EN IEC 60770-1:
Response timeAccording to DIN EN IEC 61298-2 / DIN EN IEC 60770-1, the step response time is
Ød100 … 150 mm (4 … 6 in)
≥ 150 mm (6 in)1 600 mm (64 in)
Hmax1 050 mm (42 in)
Ambient temperature range-40 to +85 °C (–40 to +185 °F)
Process temperature–20 to +200 °C (–4 to +392 °F)
HousingIP66/68, NEMA TYPE 4X/6P
L2165 mm (6.49 in) mm (in)
B20.0 (0.79) mm (in)
Pressure equipment with permitted pressure ≤200 bar (2 900 psi)
Conductor cross-section:Solid conductor 0.2 to 0.75 mm2 (24 to 18 AWG)
Stripping length:7 to 9 mm (0.28 to 0.35 in)
Outer diameter:6 to 10 mm (0.24 to 0.4 in)
Maximum cable length:60 m (197 ft)
Ambient temperature:–40 to +80 °C (–40 to +176 °F)
AntennaPEEK-cladded, 40 mm (1.5 in) flush mount with Varivent N tube
AAusführung Prozesstemperatur ≤150 °C (302 °F)
Process temperature version ≤150 °C (302 °F)150
Process temperature version ≤200 °C (392 °F)200
FccThis device complies with Part 15 of the FCC rules. Operation is subject to the
Usable measuring rangeLength of antenna + 10 mm (0.4 in)
Measuring range1.5 m (5 ft)
Antenna typePTFE cladded flush mount, 50 mm (2 in)
Cladded antenna length40 mm (1.5 in)
Integrated antenna length20 mm (0.75 in)
Antenna length (flush mount)50 mm (2 in)
Media groupA (εr 1.4 to 1.9)
Operating frequencyApprox. 80 GHz
Transmission power - Peak power<1.5 mW
Transmission power - Average output power<70 µW
Data transmission rate31.25 kBit/s
Cladded antenna, PEEK, 20 mm1 m (3.3 ft)
Cladded antenna, PEEK, 40 mm1 m (3.3 ft)
PROFIBUS PA Manufacturer ID17 (0x11)
Ident number0x1568 or 0x9700
Profile version3.02
Cable outer diameter⌀5 to 10 mm (0.2 to 0.38 in)
Test level on DC power ports and input/output ports1 000 V line to earth
Nominal discharge current10 kA
Humidity60 % ±15 %
Non-repeatability≤ 1 mm (0.04 in)
Influence of ambient temperatureAverage TC = 2 mm/10 K
Installation instructionsIntegrated antenna, PEEK 20 mm (0.75 in)
Beam angle14 °
Beamwidth diameter WD × 0.26
Nozzle diameter D80 to 100 mm (3.2 to 4 in)
H max1 750 mm (70 in)
W = D × 0.120.61 m (2.00 ft)
W = D × 0.050.25 m (0.82 ft)
Dielectric constant of mediumεr ≥ 10
Distance from antenna to tank100 mm (4 in)
Optimum material thickness for PE1.25 mm (0.049 in)
Optimum material thickness for PTFE1.30 mm (0.051 in)
Optimum material thickness for PP1.25 mm (0.049 in)
Optimum material thickness for Perspex1.10 mm (0.043 in)
Plastic housing; process temperature–40 to +150 °C (–40 to +302 °F)
Plastic housing; process temperature with CSA C/US approval0 to +150 °C (+32 to +302 °F)
Ta+76 °C (+169 °F)
Tp0 °C (+32 °F)
Aluminum housing; process temperature–40 to +150 °C (–40 to +302 °F)
Aluminum housing, coated; process temperature–40 to +150 °C (–40 to +302 °F)
316L housing; process temperature–20 to +150 °C (–4 to +302 °F)
316L housing, hygiene; process temperature–40 to +200 °C (–40 to +392 °F)
Climate classDIN EN 60068-2-38 (test Z/AD)
Installation height as per IEC61010-1 Ed.3Generally up to 5 000 m (16 404 ft) above sea level
Degree of protectionTest as per IEC 60529 and NEMA 250-2014
IP68 test condition1.83 m under water for 24 hours
Cable entries• Thread M20, IP66/68 TYPE 4X/6P
Vibration resistanceDIN EN 60068-2-64 / IEC 60068-2-64 for 5 to 2 000 Hz 1.5 (m/s2)2/Hz
Electromagnetic compatibility (EMC)EN 61326 series and NAMUR recommendation EMC (NE21)
Maximum measured error during EMC testing< 0.5 % of the current digital measured value
Process pressure range–1 to 20 bar (–14.5 to 290 psi)
Process temperature range–40 to +200 °C (–40 to +392 °F)
Process connectionslotted nut DIN11851 DN50 PN25
Dielectric constantεr ≥ 1.2
Process temperature version A≤150 °C (302 °F)
Process temperature version B≤200 °C (392 °F)
L1127 mm (5,00 in)
Dimensions of antenna, cladded flush mount, PTFE, 50 mm (2 in), slotted nut DIN11851L1 118 mm (4.65 in); version with Ex d or XP approval +5 mm (+0.20 in)
Dimensions of antenna, cladded flush mount, PTFE, 80 mm (3 in), with Tri-Clamp DN101.6 (4") ISO2852.L1: 155 mm (6.10 in); version with Ex d or XP approval +5 mm (+0.20 in) mm (in)
Process connection suitable forDN101.6 nominal diameter with pipe inner diameter 97.6 mm (3.84 in)
Weight3.4 kg (7.50 lb) for process connection slotted nut DIN11851
Housing adapter316L / 1.4404
Antenna adapter316L / 1.4404
Antenna adapter material316L
Housing adapter material316L
Measuring range restrictionsMinimum distance between reference point R and 100% mark: A ≥ 400 mm (16 in)
Manufacturer ID17 (0x11)
Optimum material thickness1.25 mm (0.049 in)
Cladded antenna length in storage vessel40 mm (1.5 in)
Cladded antenna length in buffer vessel50 mm (2 in)
Integrated antenna length in buffer vessel20 mm (0.75 in)
Signal codingFSK ±0.5 mA over current signal
Current output4 to 20 mA with superimposed digital communication protocol HART, 2-wire
Supply voltage10.5 to 35 VDC
Nominal current4 to 20 mA
Maximum measured errorMeasuring distance up to 0.8 m (2.62 ft): max. ±4 mm (±0.16 in), Measuring dista
Beam angle α14 °
5 m (16 ft)0.25 m (0.82 ft)
10 m (33 ft)0.50 m (1.64 ft)
15 m (49 ft)0.75 m (2.46 ft)
20 m (66 ft)1.00 m (3.28 ft)
25 m (82 ft)1.25 m (4.10 ft)
30 m (98 ft)1.50 m (4.92 ft)
35 m (115 ft)1.75 m (5.74 ft)
40 m (131 ft)2.00 m (6.56 ft)
45 m (148 ft)2.25 m (7.38 ft)
50 m (164 ft)2.50 m (8.20 ft)
60 m (197 ft)3.00 m (9.84 ft)
70 m (230 ft)3.50 m (11.48 ft)
80 m (262 ft)4.00 m (13.12 ft)
100 m (328 ft)5.00 m (16.40 ft)
125 m (410 ft)6.25 m (20.51 ft)
Plastic housing material; process temperature range–20 to +150 °C (–4 to +302 °F)
Order option; process temperature range–20 to +200 °C (–4 to +392 °F)
Process temperature range with CSA C/US approval0 to +200 °C (+32 to +392 °F)
Process temperature range–20 to +150 °C (–4 to +302 °F)
316L housing material–20 to +200 °C (–4 to +392 °F)
Storage temperature• Without LCD display: –40 to +90 °C (–40 to +194 °F)
Housing and process connectionIP66/68, TYPE 4X/6P
(ip68)(1.83 mH2O for 24 h)
HAN7D plug90 degrees
Electromagnetic compatibilityEN 61326 series and NAMUR recommendation EMC (NE21)
Height with cover with plastic viewing window125.3 (4.93)
Cover without viewing window123.9 (4.88)
Weight, housing plastic0.8 kg
Weight, housing aluminum1.1 kg
Weight, housing dual compartment aluminum1.4 kg
Weight, housing dual compartment stainless steel3.3 kg
Weight, housing dual compartment L-form1.7 kg
Weight, integrated antenna PEEK1.2 kg
Weight, antenna PTFE 50 mm2.2 kg
Degree of protection (fully locked)IP67
Ambient temperature–40 to +80 °C (–40 to +176 °F), Option: –50 to +80 °C (–58 to +176 °F)
Failure mode (according to NAMUR Recommendation NE 43):Minimum alarm (= factory setting): 3.6 mA
Minimum start-up voltage10.5 V
Start-up current< 3.6 mA
Starting time< 15 s
Minimum operating voltage10.5 V
Coupling, plastic⌀5 to 10 mm (0.2 to 0.38 in)
Coupling, nickel-plated brass⌀7 to 10.5 mm (0.28 to 0.41 in)
Coupling, stainless steel⌀7 to 12 mm (0.28 to 0.47 in)
Spark-over voltagemin. 400 VDC
Tested according toIEC / DIN EN 60079-14 sub chapter 12.3 (IEC / DIN EN 60060-1 chapter 7)
Measuring distance up to 0.8 m (2.62 ft)max. ±4 mm (±0.16 in)
Measuring distance > 0.8 m (2.62 ft)±1 mm (±0.04 in)
Mounting location~ 1/6 of the vessel diameter. The device should never be mounted closer than 15
Process temperature–40 to +200 °C (–40 to +392 °F)
Pressure equipment with allowable pressure ≤200 bar (2 900 psi)
Minimum distance between reference point R and 100% markA ≥ 400 mm (16 in)
Minimum spanF ≥ 45 mm (1.77 in)
Degree of protection:IP68 / NEMA 6P
Connecting cable:up to 30 m (98 ft)
Maximaler Messbereich80 m (262 ft)
Temperatur–40 … +200 °C (–40 … +392 °F)
Druck–1 … +25 bar (–14,5 … +363 psi)
Arbeitsfrequenzca. 80 GHz
Sendeleistung<1,5 mW Peakleistung
Hersteller-id:17 (0x11)
Ident number:0x1568 oder 0x9700
Profil-version:3.02
Prüfpegel für DC-Versorgungsleitungen und IO-Leitungen1 000 V Leitung gegen Erde
Zündspannungmin. 400 VDC
Geprüftgemäß IEC/DIN EN 60079-14 Unterkapitel 12.3 (IEC/DIN EN 60060-1 Kapitel 7)
Nennableitstrom10 kA
Luftfeuchte60 % ±15 %
ReflektorMetallplatte mit Durchmesser ≥ 1 m (40 in)
Messfehler+0,02 %
Abstrahlwinkel α14 °
GewindeG1/2, IP66/68 NEMA TYPE 4X/6P
SteckerM12
Schwingungsfestigkeit1,5 (m/s2)2/Hz
Elektromagnetische Verträglichkeit (EMV)EN 61326-Serie und NAMUR-Empfehlung EMV (NE21)
Maximale Messabweichung während EMV- Prüfungen< 0,5 % der Spanne.
Ausführung Prozesstemperatur≤150 °C (302 °F)
Nominal sizeDN101.6
Funkrichtlinie EN 302372Die Geräte entsprechen der TLPR (Tanks Level Probing Radar)-Funkrichtlinie EN 30
Measuring range1,5 m (5 ft)
Kabelaußendurchmesser Kunststoff5 … 10 mm (0,2 … 0,38 in)
Kabelaußendurchmesser Messing vernickelt7 … 10,5 mm (0,28 … 0,41 in)
Kabelaußendurchmesser Edelstahl7 … 12 mm (0,28 … 0,47 in)
R0.8 (2.62) m (!)
ReaktionszeitDie folgenden Sprungantwortzeiten (gemäß DIN EN IEC 61298-2 / DIN EN IEC 60770-1
Wasserstoff+20 °C (+68 °F)
Wasser (Sattdampf)+100 °C (+212 °F)
Antenne integriertPEEK 20 mm (0,75 in)
WD × 0,26
Antenne PTFE plattiert, frontbündig50 mm (2 in)
Antenneplattiert frontbündig, PEEK, 20 mm (0,75 in)
22 m (72,18 ft)3,08 m (10,10 ft)
Prozesstemperatur0 … +200 °C
Gewicht inklusive Elektronik und Display.0,5 kg (1,10 lb)
Minimum alarm3.6 mA
Maximum alarm22 mA
Failure mode with user-configurable value3.59 to 22.5 mA
Communication resistor250 Ω
Dielektrizitätszahlεr ≥ 1,2
Spalten an Übergängenmaximal 1 mm (0,04 in)
Antennenkante zum Tankca. 100 mm (4 in)
Umgebungstemperaturbe-reichMit LCD Anzeige: –40 … +85 °C (–40 … +185 °F) mit Einschränkungen in den optisch
Kunststoffgehäuse; Prozesstemperatur–20 … +150 °C (–4 … +302 °F)
P1Tp: –20 °C (–4 °F) | Ta: +76 °C (+169 °F)
P2Tp: +76 °C (+169 °F) | Ta: +76 °C (+169 °F)
P3Tp: +150 °C (+302 °F) | Ta: +25 °C (+77 °F)
P4Tp: +150 °C (+302 °F) | Ta: –20 °C (–4 °F)
P5Tp: –20 °C (–4 °F) | Ta: –20 °C (–4 °F)
Bei Geräten mit Kunststoffgehäuse und CSA C/US Zulassungist die gewählte Prozesstemperatur von –20 … +150 °C (–4 … +302 °F) auf 0 … +150
Housing316L; Prozesstemperatur –10 … +150 °C (+14 … +302 °F)
Maximum permissible torque50 Nm (36 lbf ft)
NoticeLoosen the external locking screw by a maximum of 1.5 turns.
Measurement range1.5 m (5 ft)
Electrical connection dataU = 16 to 35 VDC, I = 0 to 40 mA
Failure mode (according to NAMUR Recommendation NE 43)Minimum alarm (= factory setting): 3.6 mA, Maximum alarm: 22 mA, Failure mode wi
3 RL max £ B23 mA
Time to establish connection< 30 s
Dielectric constant For liquidsεr ≥ 1.2
Temperature range–20 to +150 °C (–4 to +302 °F)
Einfluss der UmgebungstemperaturMittlerer TK = 2 mm/10 K
Maximum nozzle length Hmax200 mm (8 in)
Mounting nozzle length Hmax600 mm (24 in)
Cover with securing screw2x 0.7 Nm
Cover with securing screw; hygienic housing7x 0.7 Nm
Cable capacitance45 to 200 nF/km
Loop resistance15 to 150 Ω/km
Cable inductance0.4 to 1 mH/km
PlugM12
Conductor cross-sectionSolid conductor 0.2 to 0.75 mm2 (24 to 18 AWG), Fine-stranded conductor 0.2 to 0
Media group A03 m (10 ft)
Media group A6 m (20 ft)
Media group B11 m (36 ft)
Media group C15 m (49 ft)
Media group D22 m (72 ft)
Buffer vessel antenna typeIntegrated antenna, PEEK, 20 mm (0.75 in)
Buffer vessel Media group A01 m (3.3 ft)
Buffer vessel Media group A1.5 m (5 ft)
Buffer vessel Media group B3 m (10 ft)
Buffer vessel Media group C6 m (20 ft)
Buffer vessel Media group D8 m (26 ft)
Buffer vessel flush mount antenna typePTFE cladded flush mount, 50 mm (2 in)
Buffer vessel flush mount Media group A04 m (13 ft)
Buffer vessel flush mount Media group A7 m (23 ft)
Buffer vessel flush mount Media group B13 m (43 ft)
Buffer vessel flush mount Media group C28 m (92 ft)
Buffer vessel flush mount Media group D44 m (144 ft)
Profinet-apl10BASE-T1L, 2-Draht 10 Mbit/s
Cover with securing screw torque0.7 Nm
Cover with securing screw torque (hygienic housing)0.7 Nm
Antenna length in storage vessel40 mm (1.5 in)
Antenna length in buffer vessel (integrated)20 mm (0.75 in)
Antenna length in buffer vessel (flush mount)50 mm (2 in)
Integrated antennaPEEK, 20 mm (0.75 in)
process temperature (CSA C/US approval)0 to +150 °C (+32 to +302 °F)
P3 (CSA C/US approval)Tp: +150 °C (+302 °F) | Ta: +25 °C (+77 °F)
P4 (CSA C/US approval)Tp: +150 °C (+302 °F) | Ta: 0 °C (+32 °F)
P5 (CSA C/US approval)Tp: 0 °C (+32 °F) | Ta: 0 °C (+32 °F)
Ambient temperature+25 °C (+77 °F)
process temperature with CSA C/US approval0 to +150 °C (+32 to +302 °F)
Aluminum housing process temperature–40 to +200 °C
316L housing; process temperature range–40 to +150 °C (–40 to +302 °F)
Mounting torque0.7 Nm
316L housing, hygiene; process temperature range–40 to +150 °C (–40 to +302 °F)
G1/2 threadIP66/68 NEMA Type 4X/6P
NPT 1/2 threadIP66/68 NEMA Type 4X/6P
M12 plugIP66/67 NEMA Type 4X
Switch-on delay0.0 to 100.0 s
Switch-off delay0.0 to 100.0 s
MediengruppeA0 (εr 1,2 … 1,4)
Signalkodierung:FSK ±0,5 mA über dem Stromsignal
Datenübertragungsrate:1 200 Bit/s
Stromausgang4 … 20 mA mit überlagertem digitalem Kommunikationsprotokoll HART, 2-Draht
Minimaler Alarm3,6 mA
Maximaler Alarm22 mA
Spannungsversorgung10,5 … 30 VDC Ex i
Rlmax1065 W
Bemessungsquerschnitt Versorgungsspannung0,5 … 2,5 mm2 (20 … 13 AWG)
Bemessungsquerschnitt Externe Erdungsklemme0,5 … 4 mm2 (20 … 12 AWG)
ReferenzbedingungenTemperatur = +24 °C (+75 °F) ±5 °C (±9 °F)
Antennenlänge80 mm (3 in)
D5 m (16 ft)
Optimale Materialdicke1,25 mm (0,049 in)
Prozesstemperaturbereich–40 … +200 °C (–40 … +392 °F)
Prozesstemperaturbereich bei CSA C/US Zulassung0 … +200 °C (+32 … +392 °F)
KlimaklasseDIN EN 60068-2-38 (Prüfung Z/AD)
Einsatzhöhe nach IEC61010-1 Ed.3bis 2 000 m (6 600 ft) über Normalnull
SchutzartIP66/68, NEMA TYPE 4X/6P
Prozessdruckbereich–1 … 25 bar (–14,5 … 362,6 psi)
Temperaturbereich Dichtung–40 … +150 °C (–40 … +302 °F)
Abmessungen Antenne integriert, PEEK, 20 mm / M24×1,5. Maßeinheit mm (in)A Ausführung Prozesstemperatur ≤150 °C (302 °F)
B Ausführung Prozesstemper
Gewicht Gehäuse Kunststoff0,8 kg (1,76 lb)
Reichweitebis zu 25 m (82 ft)
Kunststoffgehäuse; Prozesstemperatur bei CSA C/US Zulassung0 … +200 °C (+32 … +392 °F)
Gehäuse Aluminium, beschichtet; Prozesstemperatur–20 … +150 °C (–4 … +302 °F)
Gewicht Gehäuse Aluminium1,2 kg (2,65 lb)
Gewicht Gehäuse 316L Hygiene1,2 kg (2,65 lb)
Gewicht Gehäuse Zweikammer Aluminium1,4 kg (3,09 lb)
Gewicht Gehäuse Zweikammer L-Form Aluminium1,7 kg (3,75 lb)
Gewicht Gehäuse Zweikammer L-Form Edelstahl4,5 kg (9,9 lb)
Gewicht Antenne integriert PEEK1,2 kg (2,65 lb)
Gewicht Antenne plattiert frontbündig PTFE 50 mm2,2 kg (4,85 lb) bei Prozessanschluss Nutmutter DIN11851
Nutzbarer Messbereich50 … 80 mm (1,97 … 3,15 in)
Stromausgang 1 Betriebsarten4,0 … 20,5 mA, NAMUR NE 43: 3,8 … 20,5 mA (Werkeinstellung), US mode: 3,9 … 20,8
Stromausgang 2 Betriebsarten4,0 … 20,5 mA, NAMUR NE 43: 3,8 … 20,5 mA (Werkeinstellung), US mode: 3,9 … 20,8
Schaltausgang Elektrische AnschlusswerteU = 16 … 35 VDC, I = 0 … 40 mA
Schaltausgang InnenwiderstandRI < 880 Ω
IsolationsspannungenPotenzialfrei, Isolationsspannung 1 350 VDC gegen Spannungsversorgung und 500 VA
SchaltverzögerungFrei programmierbar im Bereich 0 … 100 s, getrennt für Ein- und Ausschaltpunkt
Fehlerverhalten (gemäß NAMUR-Empfehlung NE 43)Minimaler Alarm (= Werkseinstellung): 3,6 mA, Maximaler Alarm: 22 mA, Fehlerverh
Bürde4 … 20 mA passiv
U –10.5 V
3 R L max £ B23 mA
Minimale Anlaufspannung10,5 V
Anlaufstrom< 3,6 mA
Anlaufzeit< 15 s
Minimale Betriebsspannung10,5 V
Zeit für Verbindungsaufbau< 30 s
Elektromagnetische VerträglichkeitEN 61326-Serie und NAMUR-Empfehlung EMV (NE21)
Leiterquerschnitt Eindrähtiger Leiter0,2 … 0,75 mm2 (24 … 18 AWG)
Leiterquerschnitt Feindrähtiger Leiter0,2 … 0,75 mm2 (24 … 18 AWG)
Leiterquerschnitt Feindrähtiger Leiter; mit Aderendhülse mit Kunststoffkragen0,25 … 0,34 mm2
Leiterquerschnitt Feindrähtiger Leiter; mit Aderendhülse ohne Kunststoffkragen0,25 … 0,34 mm2
Abisolierlänge7 … 9 mm (0,28 … 0,35 in)
Außendurchmesser6 … 10 mm (0,24 … 0,4 in)
Maximale Kabellänge60 m (197 ft)
Umgebungstemperatur–40 … +80 °C (–40 … +176 °F)
Option: Umgebungstemperatur–50 … +80 °C (–58 … +176 °F)
Mediengruppe A0 (εr 1,2 … 1,4)1,5 m
Mediengruppe A (εr 1,4 … 1,9)2,5 m
Mediengruppe D (εr >10)10 m
Antenne PTFE plattiert frontbündig, 50 mm50 mm
Antenne PTFE plattiert frontbündig, 80 mm80 mm
Antenne PEEK plattiert frontbündig, 20 mm20 mm
Antenne PTFE plattiert frontbündig80 mm (3 in) im Pufferbehälter
Antenne PEEK plattiert frontbündig20 mm (0,75 in) im Pufferbehälter
Antenne integriert, PEEK20 mm (0,75 in)
Sendeleistung Peakleistung<1,5 mW
Sendeleistung Mittlere Ausgangsleistung<70 µW
Bemessungsquerschnitt Schutzleiter oder Erdung des Kabelschirms> 1 mm2 (17 AWG)
Kabelaußendurchmesser Verschraubung Kunststoff⌀5 … 10 mm (0,2 … 0,38 in)
Kabelaußendurchmesser Verschraubung Messing vernickelt⌀7 … 10,5 mm (0,28 … 0,41 in)
Kabelaußendurchmesser Verschraubung Edelstahl⌀7 … 12 mm (0,28 … 0,47 in)
Kabelkapazität45 … 200 nF/km
Schleifenwiderstand15 … 150 Ω/km
Kabelinduktivität0,4 … 1 mH/km
Referenzbedingungen Temperatur+24 °C (+75 °F) ±5 °C (±9 °F)
Referenzbedingungen Druck960 mbar abs. (14 psia) ±100 mbar (±1,45 psi)
Referenzbedingungen Luftfeuchte60 % ±15 %
Maximale Messabweichung Messdistanz bis 0,8 m (2,62 ft)max. ±4 mm (±0,16 in)
Maximale Messabweichung Messdistanz > 0,8 m (2,62 ft)±1 mm (±0,04 in)
Nichtwiederholbarkeit≤ 1 mm (0,04 in)
Maximale Stutzenlänge Hmax in Abhängigkeit vom Stutzendurchmesser D80 … 100 mm (3,2 … 4 in) 1 750 mm (70 in)
W = D × 0,261,23 m (4,04 ft)
W = D × 0,120,61 m (2,00 ft)
W = D × 0,050,25 m (0,82 ft)
W = D × 0,140,70 m (2,29 ft)
Prozesstemperatur (mit CSA C/US Zulassung)0 … +150 °C (+32 … +302 °F)
ProzessanschlussgewindeM24
Abmessungen Antenne plattiert frontbündig, PTFE, 50 mm (2 in), Nutmutter DIN11851A: Ausführung Prozesstemperatur ≤150 °C (302 °F), B: Ausführung Prozesstemperatu mm (in)
Prozesstemperatur A≤150 °C (302 °F)
Prozesstemperatur B≤200 °C (392 °F)
Weight3,4 kg (7,50 lb)
Process connection316L / 1.4404
Gehäuseadapter316L / 1.4404
Antennenadapter316L / 1.4404
Mindestabstand zwischen Referenzpunkt R und 100%-Marke400 mm
Minimale Spanne45 mm
Maximalwert für Abgleich Leer450 mm
Genauigkeit±1 mm (±0,04 in)
Standard:–40 … +85 °C (–40 … +185 °F)
Optional bestellbar:–50 … +85 °C (–58 … +185 °F)
Mit LCD Anzeige:–40 … +85 °C (–40 … +185 °F)
IP Schutzklasse Gehäuse geschlossen, Kabel eingestecktIP66/67 NEMA TYPE 4X
IP Schutzklasse Gehäuse offen oder Kabel nicht eingestecktIP20 NEMA TYPE 1
Maximale Stutzenlänge Hmax200 mm (8 in)
Feststellschraubemaximal 1,5 Umdrehungen
Sicherungsschraubemaximal 3,5 Nm (2,58 lbf ft) ± 0,3 Nm (0,22 lbf ft)
Anzeigemodulmaximal 4 × 90 ° in jede Richtung
Schraube der Deckelsicherung0,7 Nm (0,52 lbf ft) ±0,2 Nm (0,15 lbf ft)
Ex-frei, Ex d, Ex e9 … 32 VDC
Ex i9 … 30 VDC
Nennstrom14 mA
Antenne integriert, PEEK, 20 mm0,75 in im Behälter mit Rührwerk
Prozesstemperatur bei CSA C/US Zulassung0 … +150 °C (+32 … +302 °F)
Mittlere Ausgangsleistung63 µW
Datenübertragungsrate1 200 Bit/s
Betriebsarten• 4,0 … 20,5 mA
• NAMUR NE 43: 3,8 … 20,5 mA (Werkeinstellung)
• US mode: 3,9 …
Fehlerverhalten• Minimaler Alarm (= Werkseinstellung): 3,6 mA
• Maximaler Alarm: 22 mA
Einkammer Gehäuse316L Hygiene (keine Feststellschraube)
Failure current FDE0 mA
Multidrop-strom4 mA
Fehlerstrom FDE (Fault Disconnection Electronic)0 mA
Process temperature (CSA C/US approval)0 to +200 °C (+32 to +392 °F)