Measuring rangeup to 38 m (125 ft)
Precision0.8 mm (0.03 in)
ApprovalsNMi, PTB
Process connectionGas-tight
Power supply4-20 mA with HART
Wire diameters0.5 to 2.5 mm² [20 to 14 AWG]
Awg[20 to 14]
CommunicationStandard U (20 mA) = 16 V 36
Power consumptionMax. 330 mW at 16 V, max. 500 mW at 24 V, max. 600 mW at 30 V.
Current consumptionMax. 21 mA (50 mA inrush current).
Ripple HART47 to 125 Hz: Uss = 200 mV (at 500 )
Max. noise HART500 Hz...10 kHz: Ueff = 2.2 mV (at 500 Ω)
Maximum measured errorbetter than ±1 mm (0.04 in)
Resolution• digital: 0.1 mm
• analog: 0.03 % of measuring ran
Settling timeTypical 15 sec
Hysteresis0.3 mm (1/64"
Non-repeatability0.3 mm (1/64"
Influence of ambiente temperatureWithin the specified accuracy according to OIML R85.
Maximum fill speedBy the first pass trough of measuring range: 100 mm/min., after it unlimited.
Ambient temperature range-40 °C to +80 °C (-40 °F to +176 °F)
For custody transfer measurement-25 °C to +55 °C (-13 °F to +131 °F)
Storage temperature-40 °C to +80 °C (-40 °F to +176 °F)
Climate classDIN EN 60068-2-38 (test Z/AD)
Degree of protectionIP65/68, NEMA 4X/6P
Vibration resistanceDIN EN 60068-2-64 / IEC 68-2-64: 20 to 2000 Hz, 1 (m/s2)2/Hz
Process temperature range-40 °C to +150 °C (-40 °F to 302 °F)
Process pressure limits0 to 25 bar (0 to 375 psi)
Dielectric constantIn a stilling well: εr ≥ 1.4
In free space: εr ≥ 1.9
A68 (2.68) mm [in]
B65 (2.56) mm [in]
Ød129 (5.08) mm [in]
B8 (0.31) mm [in]
L238 (9.37) mm [in]
2Endress+Hauser UNI flange (max. 1 bar (15 psi)) mm [in]
MaterialAlSi10Mg
Measuring rangeup to 38 m (125 ft)
Precision0.8 mm (0.03 in) (2 value)
Signal ExU (4 mA) = 11.5 V 30 V
Measuring range B0.5 (1.6) m (ft)
A (mm [in])68 (2.68) mm [in]
B (mm [in])65 (2.56) mm [in]
øD (mm [in])129 (5.08) mm [in]
B (mm [in])238 (9.37) mm [in]
L (mm [in])111 (4,37)
MaulburgIP 65
Measuring rangebis 38 m (125 ft)
Präzision0,8 mm (0,03 in)
Energieversorgung4-20 mA mit HART
Leiterquerschnitte0,5…2,5 mm² [20…14 AWG]
Klemmenspannung minimal16 V
Klemmenspannung maximal36 V
Leistungsaufnahme max700 mW
Stromaufnahme Max21 mA
Referenzbedingungen Temperatur-25 °C... +55 °C (-13 °F...+131 °F)
Typische Genauigkeit±0,8 mm
Digital Auflösung0,1 mm
Analog Auflösung0,03 % des Messbereichs
EinschwingzeitTypisch 15 sec
Hysterese0,3 mm (0,01 in)
Widerholbarkeit0,3 mm (0,01 in)
Einfluss der UmgebungstemperaturInnerhalb der spezifizierten Messabweichung nach OIML R85.
Maximale BefüllgeschwindigkeitWährend des ersten Durchfahren des Füllstandbereiches: 100 mm/min, danach unbesc
SchwallrohraufweitungDN150 auf DN200 / DN200 auf DN250 / DN250 auf DN300
HousingT12, aluminum
Cover (Display)AlSi10Mg
SealFa. SHS: EPDM 70pW FKN
Ip65
Spalt<5 mm (0,2 in)
Umgebungstemperaturbereich-40 °C...+80 °C (-40 °F...+176 °F)
KlimaklasseDIN EN 60068-2-38 (Prüfung Z/AD)
SchutzartIP65/68, NEMA 4X/6P
SchwingungsfestigkeitDIN EN 60068-2-64 / IEC 68-2-64: 20…2000 Hz, 1 (m/s2)2/Hz
Prozesstemperaturbereich-40 °C…+150 °C (-40 °F...302 °F)
Prozessdruckgrenze0…25 bar (0...375 psi)
Dielektrizitätszahlr 1,4
Ø129ø129 (5.08) mm (in)
Flansch / ProzessanschlussJPI 7S -15
Antenne6" 150 mm
Ød (mm [in])192 (7,56)
Material316L (1.4435)
Deckel (Display)AlSi10Mg
SealFa. SHS: EPDM 70pW FKN
SichtscheibendichtungSilikondichtungsmasse Gomastit 402
Adapter316L (1.4435), AlMgSiPb (eloxiert)
Deckel (Anschlussraum)AlSi10Mg
DeckeldichtungFa. SHS: EPDM 70pW FKN, Trelleborg: EPDM E7502/E7515
DichtringFa. SHS: EPDM 70pW FKN, Trelleborg: EPDM E7502/E7515
Anhängeschild304 (1.4301)
Typenschild316L (1.4404)
KerbnagelA4 (1.4571)
SchraubeA2-70
ÜberfüllsicherungWHG, siehe ZE00243F/00/DE.
FunkzulassungR&TTE 1999/5/EG, FCC CRF 47, part 15
Eich-bauartzulassungAlle Aspekte der OIML R85 werden erfüllt.
Präzision (2 Wert)0,8 mm (0,03 in)
Klemmenbelegung4-20 mA mit HART
LeistungsaufnahmeMax. 330 mW bei 16 V, max. 500 mW bei 24 V, max. 600 mW bei 30 V.
StromaufnahmeMax. 21 mA (50 mA Einschaltstrom).
Temperatur:-25 °C... +55 °C (-13 °F...+131 °F)
Luftfeuchte:65 % ±15 %
Absolute Genauigkeit:besser als ±1 mm (0,04 in)
Digital:0,1 mm
Analog:0,03% des Messbereichs
Blockdistanz (BD)1 (3,3) m (ft)
Sicherheitsdistanz (SD)0,5 m
Eichfähig-25 °C...+55 °C (-13 °F...+131 °F)
Schutzart GehäuseIP65/68, NEMA 4X/6P
Schutzart AntenneIP65/68, NEMA 4X/6P
2 (mm [in])238 (9.37) mm [in]
Blockdistanz [m (ft)]1 (3,3)
Sicherheitsdistanz [m (ft)]0,5 (1,6)
zusätzliche empfohlene Messbedingungen A [mm (in)]1000 (39,4)
kleinste mögliche Messbereich B [m (ft)]0,5 (1,6)
Umgebungstemperaturbereich des Messumformers: Standard-40 °C...+80 °C (-40 °F...+176 °F)
Eichfähig:-25 °C...+55 °C (-13°F...+131 °F)
Inaktive Länge (mm [in])60 (2.36) mm [in]
Ausgang4 mA und 20 mA, für digitale Ausgänge und das Anzeigemodul 0 % und 100 %
Klemme Spannung minimal16 V
Klemme Spannung maximal36 V
Messabweichung Absolute Genauigkeit:besser als ±1 mm (0,04 in)
Auflösung Digital:0,1 mm
Einschwingzeit Typisch:15 Sekunden
Blockdistanz (BD) [m (ft)]1 (3,3) m (ft)
Sicherheitsdistanz (SD) [m (ft)]0,5 (1,6) m (ft)
Ø129 (mm [in])ø129 (5.08) mm [in]
238 (mm [in])238 (9.37) mm [in]
8 (mm [in])8 (0.31) mm [in]
111 (mm [in])111 (4.37) mm [in]
98 (mm [in])98 (3.86) mm [in]
Ø150 (mm [in])ø150 (5.91) mm [in]
Measured value4 to 20 mA HART
TAntenne max.70°C
Housing:C T12 Alu, coated IP65 NEMA4X, separate conn. compartment
Cable entry:2 Gland M20
3 Thread G1/2
4 Thread NPT1/2
9 Special version, TSP-No. to
Supply voltageDC voltage: 16…36 VDC
Terminal voltageU (20 mA) = 16 V
SignalU (20 mA) = 11.5 V
Load HARTMinimum load for HART communication: 250 Ω
Cable entryCable gland: 2 x M20x1.5
Cable entry: 2 x G ½ o
Minimum load for HART communication:250 Ω
Terminal voltage minimum16 V
Maximum36 V
U (4 mA) =11.5 V
U (20 mA) =11.5 V
Optimale Einbauposition90°
Schrittweite der RohraufweitungDN150 auf DN200 / DN200 auf DN250 / DN250 auf DN300
Mindestlänge zwischen oberem Rohrende und Aufweitung0,5 m
HousingC T12 Alu, besch. IP65 NEMA4X, getrennter Anschlussraum
Kabeleinführung2 Verschr. M20, 3 Gewinde G1/2, 4 Gewinde NPT1/2
max. zulässiger Druck im Behälter0560
Zulassungs-nr.D00676-F
U:16...30 VDC
Min. Bürde für HART-Kommunikation:250 Ω
Gleichspannung:16…36 V DC
VersorgungU (20 mA) = 16 V 36 V
ExU (20 mA) = 16 V 30 V
Max. Leistungsaufnahme bei 16 V330 mW
Max. Leistungsaufnahme bei 24 V500 mW
Max. Leistungsaufnahme bei 30 V600 mW
Max. Leistungsaufnahme bei 36 V700 mW
Max. Stromaufnahme21 mA (50 mA Einschaltstrom)
Speisung≥250Ω
Rauschen HART500 Hz...10 kHz Ueff = 2,2 mV (bei 500 Ω)
Bürde HARTMin. Bürde für HART-Kommunikation: 250 Ω
Versorgungsspannung"Versorgungsspannung", → ä 24
Wiederholbarkeit0,3 mm
Einfluss der Umgebungstemp.Innerhalb der spezifizierten Messabweichung nach OIML R85
Max. Befüllgeschwindigkeit100 mm/min
Auflösung• digital: 0,1 mm
• analog: 0,03 % des Messbereichs
SoftwarezuverlässigkeitDie Software der Radargeräte Micropilot S erfüllt die Anforderungen der OIML R85
Ausgangssignal4…20 mA mit HART-Protokoll
Max. Prozesstemperatur85°C
Klemmenspannung16 V minimal
ReferenzbedingungenNach OIML R85: • Temperatur = -25 °C... +55 °C • Atmosphärischer Druck • Luftfeu
Max. measuring range in tank0560
Basic weight6.5 kg
Output signal4…20 mA with HART protocol
Software reliabilityThe software used in the radar instruments FMR 53x fulfills the requirements of
Outputpassive 4…20 mA
Blocking distance (BD)11 m/40"
Length of horn390 mm/15"
Additional weight1.1 kg
Antenna150mm/6", HNBR, Planar
Grundgewicht6,5 kg
Mehrgewicht1,1 kg
Temperatur-40 bis +150 °C
DruckVakuum bis +25 bar
Rohraufweitungvon DN150 auf DN200 / DN200 auf DN250 / DN250 auf DN300
Mindestlänge0,5 m zwischen oberem Rohrende und Aufweitung
LöcherDurchmesser (entgratet) kann 1/7 des Rohrdurchmessers betragen, sollte aber 30 m
Mediumberührte Teile1.4435 / HNBR (Hydrierter Nitrit Butadien Kautschuk,) oder FKM / PTFE-Glasfaser-
Hornaufweitung1.4435
Weight6,5 kg
DC voltage16…36 VDC
Influence of ambienteWithin the specified accuracy according to OIML R85
Dimensions68 (2.68') 94 (3.7')
Ø129 (5.08')
Dn150 / 6"
Version without wideningDN200…300 / 8…12"
BD [m / ft]1 / 3.28 m / ft
SD [m / ft]0.5 / 1.6 m / ft
A [mm / inch]1000 / 40 mm / inch
B [m / ft]0.5 /1.64 m / ft
C [mm / inch]150...300/6...12 mm / inch
Signal ExU (20 mA) = 11.5 V 30 V
Maximum permissible filling speed100 mm level change / min
Pipe diam. corr.(032)
Influence of ambiente temperatureWithin the1 specified accuracy according to OIML R85
Elektrische AnschlüsseGehäuse T 12 mit separatem Anschlussraum.
MessabweichungAbsolute Genauigkeit: 0,5 mm (2σ Wert)
Inventory Control Versionen: ±3 mm
Umgebungstemperatur des Messumformers-40 °C ... +80 °C
Umgebungstemperatur des Messumformers (Eichfähig)-25 °C ... +60 °C
Schutzart (Antenne)IP 68 (NEMA 6P)
Operating frequencyabout 6 GHz
Maximum radiated pulsed energy1mW
max. abgestrahlte Pulsenergie1 mW (mittlere Leistung)
abgestrahlte Pulsenergie1 mW
Arbeitsfrequenzca. 6 GHz
maximale abgestrahlte Pulsenergie1 mW
Power consumption max700 mW
Current consumption Max21 mA
Maximum measured error - Absolute accuracybetter than ±1 mm
Resolution - Digital0.1 mm
Resolution - Analog0.03 % of measuring range
Maximum fill speed - By the first pass through measuring range100 mm/min.
IP ratingIP 65