OceanSphereFree accountLog inDEENPL
OceanSphereENGINES
Library› Engine Room› Automation & Control› Level Switch› Endress+Hauser Liquiphant FTL63

Liquiphant FTL63

Level Switch · Automation & Control

Class-certified type (DNV register) · technical data sheet not yet verified

Specifically developed for the food and beverage and life sciences industries, the Liquiphant FTL63 is compliant to all their hygienic requirements. The proven vibronic technology works reliably in all pumpable liquids, even where other measuring principles reach their limits due to changes in conductivity or dielectric constant (DC value), deposits, foam, turbulences or air bubbles. Therefore, the technology is the perfect substitute for float switches, capacitive or optical sensors.

Specifications

Technical data.reference — unverified

Schutzart GrundgerätIP20
Schutzart Abgesetzte Bedien- und AnzeigeeinheitFront IP65
StöraussendungIEC 61326 Klasse A
Netzausfall20 ms, kein Einfluss
EinschaltstrombegrenzungImax/In <50 % (T 50 % ≤ 50 ms)
Elektromagnetische Felder10 V/m (3,048 V/ft) nach IEC 61000-4-3
HF leitungsgeführt0,15 … 80 Hz, 10 V nach IEC 61000-4-3
Elektrostatische Entladung6 kV Kontakt, indirekt nach IEC 61000-4-2
Burst-Impulse - Spannungsversorgung2 kV nach IEC 61000-4-4
Burst-Impulse - Signal1 kV/2 kV nach IEC 61000-4-4
Spannungsspitze - AC-Spannungsversorgung1 kV/2 kV nach IEC 61000-4-5
Spannungsspitze - DC-Spannungsversorgung1 kV/2 kV nach IEC 61000-4-5
Spannungsspitze - Signal0,5 kV/1 kV nach IEC 61000-4-5
Prozesstemperaturbereich0 … 80 °C (32 … 176 °F)
Thermischer Schock≤ 120 K/s
Prozessdruckbereich–1 … +25 bar (–14,5 … +362,5 psi)
Feststoffanteil⌀ ≤ 5 mm (0,2 in)
Bluetooth® ModulVU121
ElektronikeinsatzFEL68 (2-Leiter NAMUR)
BatterieAA Lithium-Batterie 3,6 V
Downloads pro Jahrmaximal 60 Downloads
OberflächenrauheitRa < 1,5 µm (59 µin), CoC ASME BPE
OptionalRa < 0,3 µm (12 µin) mechanisch poliert (3-A, EHEDG)
prozessberührten Teile316L (1.4435) gemäß BN2 (delta Ferritgehalt < 1 %)
Dichteumschaltungρ > 0.7 g/cm³ (43,7 lb/ft³)
Storage temperature–40 to +80 °C (–40 to +176 °F)
Correction factor1.0000
Internal diameter of pipe100 mm
D84 mm (3,31 in)
R1.0012
Maximum lateral loading capacity75 Nm (55 lbf ft)
HART communication resistor250 Ω
Test level for DC power supply lines and IO lines1 000 V
Spark-over voltagemin. DC 400 V
Nominal discharge current10 kA
Bluetooth® moduleVU121
Electrical connection24/25 mm
Maximum conductor cross-section2.5 mm2 (AWG14)
Torque3.75 Nm
Ambient temperature range–40 to 70 °C (–40 to 158 °F)
Operating altitudeUp to 2 000 m (6 600 ft) above sea level
Climate classAs per IEC 60068-2-38 test Z/AD
Degree of protectionIP68 test condition: 1.83 m H2O for 24 h
Korrekturfaktor1,0042
DichterechnerQML51
Correction factor r1.0050
Temperatura-50 ... +150 °C (-58 ... +302 °F)
Part numberFTL63
Manufacturer documentation

Images from manufacturer documentation.

Photos, drawings and page previews from this model’s datasheet or catalog.

The Liquiphant FTL63 is a level switch designed for monitoring liquid levels in vessels with a wide range of ambient and process temperatures.

Applications

  • Marine vessel monitoring

Features

  • Wide temperature range
  • PROFINET over Ethernet-APL

Options

  • Single compartment housing (plastic)

Standards

  • ASME BPE
  • 3-A
  • EHEDG
Source: Endress+Hauser Liquiphant FTL63 datasheet, p. 43
Endress+Hauser Liquiphant FTL63 – Drawing (1f8279ca8ef8_S2-44 S. 3)
Drawing · 1f8279ca8ef8_S2-44 · S. 3
Endress+Hauser Liquiphant FTL63 – Drawing (1f8279ca8ef8_S2-44 S. 5)
Drawing · 1f8279ca8ef8_S2-44 · S. 5
Endress+Hauser Liquiphant FTL63 – Page preview (1f8279ca8ef8_S2-44 S. 4)
Page preview · 1f8279ca8ef8_S2-44 · S. 4
Endress+Hauser Liquiphant FTL63 – Page preview (1f8279ca8ef8_S2-44 S. 6)
Page preview · 1f8279ca8ef8_S2-44 · S. 6
Endress+Hauser Liquiphant FTL63 – Page preview (1f8279ca8ef8_S2-44 S. 7)
Page preview · 1f8279ca8ef8_S2-44 · S. 7
Endress+Hauser Liquiphant FTL63 – Page preview (1f8279ca8ef8_S2-44 S. 8)
Page preview · 1f8279ca8ef8_S2-44 · S. 8
Source: Endress+Hauser Liquiphant FTL63 datasheet, p. 21
Need this part?

Request a quote for this model.

Free of charge — send us your request for Endress+Hauser equipment. Our team checks it and replies by e-mail.

Makers and authorised dealers rarely quote marine equipment without the vessel. With these details we can check availability and prices faster; without them we may have to ask first, which can cost a few days. If you cannot share the vessel, a photo of the equipment’s rating plate does the same job — send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Level Switch.

Other models of the same equipment type, Endress+Hauser first.

By manufacturer Endress+HauserAFRISOTokyo KeisoKlay InstrumentsHanla IMSVEGA GrieshaberSetra SystemsGestraPSM InstrumentationEndress+Hauser Wetzer GmbH+CoKuk Dong LevelNakakita Seisakusho Co., Ltd.API MarineBEDIA Motorentechnik GmbH & Co.KGHeriana Co., Ltd.All manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Endress+Hauser models More like Liquiphant FTL63
Would you like to know more?

A person reads every request and replies by e-mail.

Tell us what you need for this Endress+Hauser Liquiphant FTL63 — a part, a service call, a second opinion. Are you Endress+Hauser? Claim this brand page.

Service engineer? Write the day report for this Liquiphant FTL63 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Three things people ask first.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.