Omron Industrial

CIP Safety

Description being added…

Components & Design

Component data being added…

Technical Data

Grounding method Ground to 100 Ω or less
Ambient storage temperature −25 to 70°C (with no condensation or icing)
Overvoltage category Category II: Conforms to JIS B3502 and IEC 61131-2.
Isolation method No isolation: Between the Unit power supply terminal and internal circuit
NX Unit power supply efficiency 80%
Maximum I/O power supply current 4 A
Current consumption from I/O power supply 10 mA max. (24 VDC)
External connection terminals Screwless clamping terminal block (8 terminals)
Terminal connection diagram UV/UG: Unit power supply terminalsIOV/IOG: I/O power supply terminals
Number of cascade connections The built-in switching ports support up to 50 nodes.There is no limitation when an external Ethernet switch is used.
Maximum routable Safety data length per connection 32 bytes
Number of tags per connection (=1 tag set) 32 (31 tags if Controller status is included in the tag set.)
Dimensions 30 × 100 × 71 mm (W × H × D)
I/O power supply method Not supplied.
Current capacity of I/O power supply terminals No I/O power supply terminals
NX Unit power consumption 3.35 W max. 2The cable length for the Units (Communication Control Unit and Power Supply Unit for NX Units) that supply power to the corresponding Unit must be up to 20 m.
Weight 130 g max.
Rated input voltage 24 VDC (20.4 to 28.8 VDC)
Number of safety slave connections 1
Safety input OFF voltage/OFF current 5 VDC max., 1 mA max.
Test output type Sourcing outputs (PNP)
Test output residual voltage 1.2 V max. (Between IOV and all output terminals)
Test output leakage current 0.1 mA max.
Rated voltage 24 VDC (20.4 to 28.8 VDC)
Safety output ON residual voltage 1.2 V max. (Between IOV and all output terminals)
Safety output OFF residual voltage 2 V max. (Between IOG and all output terminals)
Safety output leakage current 0.1 mA max.
source url https://industrial.omron.eu/en/products/cip-safety

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #160866 · ✓ still in production

Need spare parts for this model?

Tell us what you need for this model — we obtain the quotations for you.