Class-certified type (DNV register) · technical data sheet not yet verified

Micropilot NMR81 is used for custody transfer and inventory control applications with NMi- and PTB-approvals and meets the requirements according to OIML R85 and API 3.1B. NMR81 is particularly suited for free space applications up to 70m. The drip-off lens antenna with 80 GHz transmitting frequency produces a sharply focused beam angle of 3° and avoids obstacles even close to tank wall.

Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Minimum terminal voltage10.4 V 1)
Maximum terminal voltage29 V 1)
Relais-Schaltleistung für ohmsche Last30 VDC @ 2 A
Max. Ansprechspannung250 VAC
Min. Ansprechspannung25 VAC
Empty0 to 10 000 000 mm
Tank reference height0 to 10 000 000 mm
Vapor density0.0 to 500.0 kg/m³
Factory setting1.2 kg/m³
Pressure-25 to 25 bar
P1 position-10 000 to 100 000 mm
P1 offset-25 to 25 bar
P3 (top) manual pressure-2.5 to 2.5 bar
P3 position0 to 100 000 mm
P3 offset-2.5 to 2.5 bar
Maximum current consumption of connected HART devices24 mA
Output voltage of Ex-d module17.0 V@4 mA to 10.5 V@22 mA
Output voltage of Ex-ia module18.5 V@4 mA to 12.5 V@22 mA
Manual vapor temperature25 °C
P1 (bottom) manual pressure-25 to 25 bar
Ambient pressure0 to 2.5 bar
Type of signalAnalog (4...20mA), HART
Maximum current consumption of the connected HART devices24 mA
Output voltage of the Ex-d module17.0 V@4 mA to 10.5 V@22 mA
Output voltage of the Ex-ia module18.5 V@4 mA to 12.5 V@22 mA
Upper density0 to 3 000 kg/m³
Calibration temperature-50 to 250 °C
Linear expansion coefficient0 to 100 ppm
Wire expansion coefficient0 to 100 ppm
Minimum pressure0 to 100 bar
Safety distance0 to 10 000 mm
Hysteresis0 to 2 000 mm
User entry0 to 5 000 mm
Adresse0 … 255
Leerabgleich0 … 10 000 000 mm
Tank Referenzhöhe0 … 10 000,00 mm
Gas Temperatur manuell25 °C
Werkseinstellung1,2 kg/m³
Druck-25 ... 25 bar
P1 Position-10 000 … 100 000 mm
P1 Offset-25 … 25 bar
P3 (oben) manueller Druck-2,5 … 2,5 bar
Start Füllstand500 mm
Sicherheitsdistanz0 ... 10 000 mm
Hysterese0 ... 2 000 mm
Wasserdichte1 000 kg/m³
SignalartAnalog (4...20 mA), HART
Maximale Stromaufnahme der angeschlossenen HART-Geräte24 mA
Ausgangsspannung des Ex-d-Moduls17,0 V@4 mA bis 10,5 V@22 mA
Ausgangsspannung des Ex-ia-Moduls18,5 V@4 mA bis 12,5 V@22 mA
Kegeldurchmesser W0,61 m (2 ft)
Minimale Distanz (A)0,31 m (1 ft)
Antennengröße50 mm (2 in)
Messdistanz5 m (16 ft)
Kegeldurchmesser0,61 m (2 ft)
Zuordnung Füllstand0,0 mm
Leitungsimpedanz0 … 15
Füllstand setzen0 … 10 000,00 mm
Wasserfüllstand manuell-2 000 … 5 000 mm
Werkseinstellung Flüssigkeitstemperatur manuell25 °C
Eingabe–25 … 25 bar
Fühler Position-5 000 … 30 000 mm
Umgebungsdruck0 … 2,5 bar
Werkseinstellung Luft Dichte1,2 kg/m³
Dichte0 … 3 000 kg/m³
Temperatura-40 a +200 °C (–40 a +392 °F)
PresiónVacío hasta +16 bar (vacío hasta 232 psi)
Rango de mediciónhasta 70 m (230 ft)
Pressionevuoto fino a +16 bar (vuoto fino a +232 psi)
Campo di misurafino a 40 m (131 ft)
Stromaufnahme bei maximaler Spannung≤ 1 mA (DC)
Part numberNMR81
Manufacturer documentation

Images from manufacturer documentation.

Photos, drawings and page previews from this model’s datasheet or catalog.

The Micropilot NMR81 is a non-contact level transmitter for measuring the level of liquids in tanks and vessels.Source: Endress+Hauser Micropilot NMR81 datasheet, p. 14

Applications

  • Hydrostatic Tank Deformation

Features

  • HyTD correction value
  • Starting level

Options

  • Antenna 50mm/2"
  • Antenna 80mm/3"
  • Antenna 100mm/4"
  • Ordering feature 100 'Antenna', option AB
  • Ordering feature 100 'Antenna', option AC
  • Ordering feature 100 'Antenna', option AD
Source: Endress+Hauser Micropilot NMR81 datasheet, p. 16
Endress+Hauser Micropilot NMR81 – Drawing (3af4fa3a512f_S12-224 S. 16)
Drawing · 3af4fa3a512f_S12-224 · S. 16
Endress+Hauser Micropilot NMR81 – Drawing (3af4fa3a512f_S12-224 S. 18)
Drawing · 3af4fa3a512f_S12-224 · S. 18
Endress+Hauser Micropilot NMR81 – Drawing (3af4fa3a512f_S12-224 S. 20)
Drawing · 3af4fa3a512f_S12-224 · S. 20
Endress+Hauser Micropilot NMR81 – Page preview (3af4fa3a512f_S12-224 S. 12)
Page preview · 3af4fa3a512f_S12-224 · S. 12
Endress+Hauser Micropilot NMR81 – Page preview (3af4fa3a512f_S12-224 S. 13)
Page preview · 3af4fa3a512f_S12-224 · S. 13
Endress+Hauser Micropilot NMR81 – Page preview (3af4fa3a512f_S12-224 S. 14)
Page preview · 3af4fa3a512f_S12-224 · S. 14
Endress+Hauser Micropilot NMR81 – Page preview (3af4fa3a512f_S12-224 S. 15)
Page preview · 3af4fa3a512f_S12-224 · S. 15
Source: Endress+Hauser Micropilot NMR81 datasheet, p. 196
Need this part?

Request a quote for this model.

Free of charge — send us your request for Endress+Hauser equipment. Our team checks it and replies by e-mail.

Makers and authorised dealers rarely quote marine equipment without the vessel. With these details we can check availability and prices faster; without them we may have to ask first, which can cost a few days. If you cannot share the vessel, a photo of the equipment’s rating plate does the same job — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Radar Level Gauge.

Other models of the same equipment type, Endress+Hauser first.

By manufacturer Endress+HauserKrohneEmerson RosemountVEGATokyo KeikiBarksdaleDanfossPanasiaSiemensNORIS AutomationEmersonHanla IMSHoneywellIfm ElectronicJUMOAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Endress+Hauser models More like Micropilot NMR81
Would you like to know more?

A person reads every request and replies by e-mail.

Tell us what you need for this Endress+Hauser Micropilot NMR81 — a part, a service call, a second opinion. Are you Endress+Hauser? Claim this brand page.

Service engineer? Write the day report for this Micropilot NMR81 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Three things people ask first.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.