A pyrotechnic line‑throwing apparatus that launches a line up to 230 m using four ready‑to‑fire rockets, meeting SOLAS requirements for man‑overboard rescue and emergency signaling. The supplied category identifies the equipment as Line-Throwing Apparatus, and it is normally installed in designated bridge, lifeboat, rescue or emergency-equipment stowage positions. In that listed role, its primary purpose is to attract attention, mark distress or establish a rescue connection during an emergency. Pyrotechnics, emergency lights and line-throwing appliances use different activation methods, so storage, expiry and operating instructions are specific to the approved item. The model designation identifies the listed configuration, but no additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. The source metadata also states capacity: 230m range. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Comet (Hansson PyroTech) Line Throwing Apparatus LTA
230m range
Capacity
Emergency Equipment
Medium

Components & Design

Component data being added…

Technical Data

type line_throwing
range m 230
rockets 4
solas True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Expired, moisture-damaged or physically damaged signaling units may fail to activate or perform correctly
Battery or lamp failure on electrical emergency lights causes weak or absent indication
Corroded firing, release or trigger components cause difficult or failed activation
Damaged line, projectile or launcher parts prevent effective line-throwing operation
Poor stowage, missing instructions or inaccessible equipment delays emergency deployment

Service & Maintenance

Inspect packaging, casing, labels, expiry or service status, batteries where fitted and secure accessible stowage. Do not test pyrotechnic or line-throwing devices outside the approved procedure. Confirm crew familiarity and inventory against the vessel safety plan. Refer to manufacturer and statutory documentation for the exact figure for service and replacement criteria.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Maintain complete approved replacement units, batteries where applicable, mounting or stowage hardware and the required statutory inventory rather than attempting unauthorized repair of pyrotechnic devices.
Equipment Model #1554 · ✓ still in production