Powerallocatortm

Powerallocatortm by Kongsberg Maritime AS is a power-allocation function within a vessel energy-management architecture. It operates at automation level, using information from generators, switchboards and major consumers to coordinate available electrical power with vessel demand. Depending on the project, it may interact with generator start/stop logic, load sharing, load limitation, load shedding and propulsion or thruster demand. The system is normally presented to operators through the vessel automation or power-management workstations rather than as a standalone machinery item. Its exact functions and priorities are vessel-specific and must be confirmed from the approved power-management functional description. Compared with the physical switchgear and protection entries, this product acts primarily through supervisory control and allocation logic.

Components & Design

Component data being added…

Technical Data

Design focus Producing power more efficiently with remaining engines
Benefits Load transfer via DC-link enabled
Suitable for Vessels classed with open or closed bus operation

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Incorrect or lost generator/load measurement, causing unstable power reserve calculation or false load alarms
Communication failure with switchboards or drives, producing degraded automatic control or manual-operation fallback
Configuration or priority error, causing unwanted load shedding or insufficient reserve for propulsion demands
Controller or server failure, leading to loss of automatic power-management functions
Faulty breaker/status feedback, preventing correct generator sequencing or bus-state recognition

Service & Maintenance

Test power-management sequences, generator start/stop, load sharing, load shedding and load-limitation interfaces under controlled conditions. Check time synchronisation, network health, I/O validity and backup/restore of the approved configuration. Review alarms and event logs for recurrent communication or measurement problems before they become operational failures. Class or DP survey attention focuses on redundancy, blackout prevention, functional testing and configuration control; refer to the manufacturer documentation for the exact figure.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.