Chiller ON/OFF - FRIGOMAR Skip to content EN IT FR Sales and Services Reference List Exhibitions Download Contacts EN IT FR Sales and Services Reference List Exhibitions Download Contacts Facebook Instagram Linkedin Search Home Company Company Research and Technology Quality Reference List Case History News Air Conditioning Air Conditioning Systems Centralized Three Phase Chiller Unit INVERTER Single Phase Chiller Unit INVERTER ON/OFF Chiller Fancoils Fancoils AH Air Handling Unit Air Extranction Unit Self-Contained SCU Variable-Speed AC SCU Variable-Speed DC HE Series Accessories Switchboards Thermostats Air Conditioning Accessories Refrigeration Refrigeration Systems Centralized Custom-Made Refrigerators Cold Rooms Wine Coolers Compressors Self-Conteined Custom-Made Refrigerators Accessories Electric Switchboards Refrigeration Components Replacement Parts Ice Maker Ice Making Ice Maker Ice Maker Kits Air Condensed Ice Makers Water Condensed Ice Makers Accessories Replacement Parts Prodotti > Air Conditioning , Centralized Air Chiller ON/OFF Refrigeration unit with on-off technology for centralized air conditioning systems. Single/Three-phase Power Supply Models 600NT 18.000 BTU/h 601NT 32.500 BTU/h 602NT 45.000 BTU/h 603NT 60.000 BTU/h 604NT 120.000 BTU/h 605NT 160,000 BTU/h Compact and modular design 50% better performance compared to R407C refrigerant systems Maximum comfort, reliability and flexibility Soundproofing panels and thermal insulation for the chilled parts Thanks to the cooling power of each individual module, which reaches up to 160,000 BTU/h, the Three-phase On-off Chiller units are able to meet the needs of Megayachts over 60 meters. The modularity of our Chillers simplifies on-board installation and crew maintenance operations; Modular chillers are particularly popular in refits and refurbishments of old systems. Compact, Reliable, Modular The 410 SERIES chillers (heat pumps) offer reliability, comfort, modularity, flexibility, ease of installation but above all allow enormous energy savings. They are suitable for applications where reducing energy consumption is a priority. Performance is 50% higher than R407C systems. The extremely compact design makes the 410 SERIES units suitable for any application: new constructions and refittings. Simply silent The use of sound-absorbing panels and the thermal insulation of the cold parts allow a drastic reduction in sound levels as well as the absence of condensation phenomena, without the need for condensate drainage, to the benefit of ease of installation. Technical Specifications 600NT 601NT 602NT 603NTQM 603NTLM 603NTQT 603NTLT 604NTQT 605NTQT 600NT Width 290 mm Height 380 mm Depth 525 mm Weight 33 Kg Voltage / phase / frequency 230 V / 1 / 50 Hz Maximum cooling/heating capacity 18.000 BTU/h Maximum current 4,1 A R410A refrigerant gas 0,5 kg Operating limits: Sea water temperature for heating > 4°C Operating limits: Sea water temperature for cooling < 45°C It is possible to have the control panel with respect to the pipes in frontal position “602NTP” or lateral “602NTS” Power input Summer operation – Cooling Sea water temperature Power input 20°C 0,59 kW 28°C 0,64 kW 35°C 0,76 kW 40°C 0,79 kW Power input Winter operation – Heating Sea water temperature Power input 5°C 0,84 kW 10°C 0,85 kW 14°C 0,86 kW 20°C 0,89 kW 601NT Width 290 mm Height 410 mm Depth 525 mm Weight 41 Kg Voltage / phase / frequency 230 V / 1 / 50 Hz Maximum cooling/heating capacity 32.500 BTU/h Maximum current 6,9 A R410A refrigerant gas 0,65 kg Operating limits: Sea water temperature for heating > 4°C Operating limits: Sea water temperature for cooling < 45°C It is possible to have the control panel with respect to the pipes in frontal position “602NTP” or lateral “602NTS” Power input Summer operation – Cooling Sea water temperature Power input 20°C 0,89 kW 28°C 1,03 kW 35°C 1,17 kW 40°C 1,34 kW Power input Winter operation – Heating Sea water temperature Power input 5°C 1,30 kW 10°C 1,35 kW 14°C 1,39 kW 20°C 1,40 kW 602NT Width 400 mm Height 510 mm Depth 550 mm Weight 63 Kg Voltage / phase / frequency 230 V / 1 / 50 Hz Maximum cooling/heating capacity 45.000 BTU/h Maximum current 11,2A (5,5A – 3ph) R410A refrigerant gas 1,3 kg Operating limits: Sea water temperature for heating > 4°C Operating limits: Sea water temperature for cooling < 45°C It is possible to have the control panel with respect to the pipes in frontal position “602NTP” or lateral “602NTS” Power input Summer operation – Cooling Sea water temperature Power input 20°C 1,55 kW 28°C 1,70 kW 35°C 1,95 kW 40°C 2,13 kW Power input Winter operation – Heating Sea water temperature Power input 5°C 2,15 kW 10°C 2,18 kW 14°C 2,20 kW 20°C 2,40 kW 603NTQM Width 470 mm Height 540 mm Depth 530 mm Weight 72 Kg Voltage / phase / frequency 230 V / 1 / 50 Hz Maximum cooling/heating capacity 60.000 BTU/h Maximum current 17 A R410A refrigerant gas 1,3 kg Operating limits: Sea water temperature for heating > 4°C Operating limits: Sea water temperature for cooling < 45°C Available only for refit It is possible to have the control panel with respect to the pipes in front position “603NTQMP / 603NTQTP” or lateral “603NTQMS / 603NTQTS”. Soft Start available on request. Power input Summer operation – Cooling Sea water temperature Power input 20°C 2,26 kW 28°C 2,50 kW 35°C 3,00 kW 40°C 3,36 kW Power input Winter operation – Heating Sea water temperature Power input 5°C 3,30 kW 10°C 3,40 kW 14°C 3,50 kW 20°C 3,60 kW 603NTLM Width 700 mm Height 620 mm Depth 280 mm Weight 72 Kg Voltage / phase / frequency 230 V / 1 / 50 Hz Maximum cooling/heating capacity 60.000 BTU/h Maximum current 17 A R410A refrigerant gas 1,3 kg Operating limits: Sea water temperature for heating > 4°C Operating limits: Sea water temperature for cooling < 45°C It is possible to have the control panel with respect to the pipes in front position “603NTQMP / 603NTQTP” or lateral “603NTQMS / 603NTQTS”. Soft Start available on request. Power input Summer operation – Cooling Sea water temperature Power input 20°C 2,26 kW 28°C 2,50 kW 35°C 3,00 kW 40°C 3,36 kW Power input Winter operation – Heating Sea water temperature Power input 5°C 3,30 kW 10°C 3,40 kW 14°C 3,50 kW 20°C 3,60 kW 603NTLT Width 470 mm Height 540 mm Depth 530 mm Weight 72 Kg Voltage / phase / frequency 200 V / 3 / 50-60 Hz 400 V / 3 / 50-60 Hz Maximum cooling/heating capacity 60.000 BTU/h Maximum current 6,5 A – 3ph R410A refrigerant gas 1,3 kg Operating limits: Sea water temperature for heating > 4°C Operating limits: Sea water temperature for cooling < 45°C Available only for refit It is possible to have the control panel with respect to the pipes in front position “603NTQMP / 603NTQTP” or lateral “603NTQMS / 603NTQTS”. Soft Start available on request. Power input Summer operation – Cooling Sea water temperature Power input 20°C 2,26 kW 28°C 2,50 kW 35°C 3,00 kW 40°C 3,36 kW Power input Winter operation – Heating Sea water temperature Power input 5°C 3,30 kW 10°C 3,40 kW 14°C 3,50 kW 20°C 3,60 kW 603NTLT Width 700 mm Height 620 mm Depth 280 mm Weight 72 Kg Voltage / phase / frequency 200 V / 3 / 50-60 Hz 400 V / 3 / 50-60 Hz Maximum cooling/heating capacity 60.000 BTU/h Maximum current 6,5 A – 3ph R410A refrigerant gas 1,3 kg Operating limits: Sea water temperature for heating > 4°C Operating limits: Sea water temperature for cooling < 45°C It is possible to have the control panel with respect to the pipes in front position “603NTQMP / 603NTQTP” or lateral “603NTQMS / 603NTQTS”. Soft Start available on request. Power input Summer operation – Cooling Sea water temperature Power input 20°C 2,26 kW 28°C 2,50 kW 35°C 3,00 kW 40°C 3,36 kW Power input Winter operation – Heating Sea water temperature Power input 5°C 3,30 kW 10°C 3,40 kW 14°C 3,50 kW 20°C 3,60 kW 604NTQT Width 530 mm Height 670 mm Depth 600 mm Weight 120 Kg Voltage / phase / frequency 230 V / 3 / 50-60 Hz 400 V / 3 / 50-60 Hz Maximum cooling/heating capacity 120.000 BTU/h Maximum current 14,9 A – 3ph R410A refrigerant gas 2.8 kg Operating limits: Sea water temperature for heating > 4°C Operating limits: Sea water temperature for cooling < 40°C Soft Start available on request. Power input Summer operation – Cooling Sea water temperature Power input 20°C 5,39 kW 28°C 6,55 kW 35°C 7,4 kW 40°C 7.9 kW Power input Winter operation – Heating Sea water temperature Power input 5°C 6,90 kW 10°C 7,10 kW 14°C 7,28 kW 20°C 7,31 kW 605NTQT Width 540 mm Height 740 mm Depth 880 mm Weight 135 kg Voltage / phase / frequency 380 V / 3 / 50-60 Hz Maximum cooling/heating capacity 160,000 BTU/h Maximum current 17.6 A – 3ph R410A refrigerant gas 2.8 kg Operating limits: Sea water temperature for heating > 5°C Operating limits: Sea water temperature for cooling < 40°C Soft Start available on request. Power input Summer operation – Cooling Sea water temperature Power input 20°C 5.7 kW 28°C 6.3 kW 35°C 6.6 kW 40°C 7.0 kW Power input Winter operation – Heating Sea water temperature Power input 5°C 7.6 kW 10°C 7.9 kW 14°C 8.2 kW 20°C 8.3 kW Search Contacts FRIGOMAR SRL Via Vittorio Veneto, 112-114-116 16042 Carasco (GE), Italy P.IVA 00168230993 Company Sales and Services Contacts Quality Reference List Products Air Conditioning Refrigeration Ice Maker Accessories Follow Facebook Instagram Linkedin Subscribe to FRIGOMAR Newsletter Language Italiano English Français Email Send FRIGOMAR © All rights reserved | Privacy Policy | Cookie Policy Made by CPLWEB.IT The Company reserves the right to make changes to product information without prior notice. Projects co-financed by the European Union →