BlueCool F1000 FreshAir

Webasto BlueCool F1000 FreshAir — Fresh air ventilation unit for large yachts; cooled and filtered ventilation; EC blower; F7 filter option.

Components & Design

Component data being added…

Technical Data

cooling capacity kW 15
airflow m3h up to 1000
weight kg 65
dimensions mm 760 x 550 x 650
voltage 230 V / 50–60 Hz

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Sea-water strainer and heat exchanger: inspect for marine fouling, corrosion, and blockage; clean titanium or cupro-nickel condenser surfaces at each service in

Sea-water strainer and heat exchanger: inspect for marine fouling, corrosion, and blockage; clean titanium or cupro-nickel condenser surfaces at each service interval

Refrigerant circuit: check operating pressures and temperatures, inspect for leaks at flare fittings and brazed joints, verify refrigerant charge (R32 or R410A)

Refrigerant circuit: check operating pressures and temperatures, inspect for leaks at flare fittings and brazed joints, verify refrigerant charge (R32 or R410A)

Chilled-water circuit: verify flow rate and pressure drop, check pump operation, inspect for air locks, test glycol concentration (freeze/corrosion protection)

Chilled-water circuit: verify flow rate and pressure drop, check pump operation, inspect for air locks, test glycol concentration (freeze/corrosion protection)

Compressor and electrical: inspect inverter drive, check running current against nameplate, verify soft-start or variable-speed control board, inspect wiring an

Compressor and electrical: inspect inverter drive, check running current against nameplate, verify soft-start or variable-speed control board, inspect wiring and terminals for corrosion

Condensate drainage: clean condensate pans and drain lines on air handlers (A-Series / F-Series); test Instant Drain system if fitted

Condensate drainage: clean condensate pans and drain lines on air handlers (A-Series / F-Series); test Instant Drain system if fitted

Filter inspection: replace G3 or F7 air filters in FreshAir units; clean evaporator coil fins as needed

Filter inspection: replace G3 or F7 air filters in FreshAir units; clean evaporator coil fins as needed

Vibration isolation and mountings: check anti-vibration mounts, hose connections, and flexible pipe couplings for wear or deterioration

Vibration isolation and mountings: check anti-vibration mounts, hose connections, and flexible pipe couplings for wear or deterioration

Controls and safety devices: test high/low pressure cut-outs, water-flow switches, and thermostatic controls; update firmware on BlueCool MyTouch / BlueCool Con

Controls and safety devices: test high/low pressure cut-outs, water-flow switches, and thermostatic controls; update firmware on BlueCool MyTouch / BlueCool Connect gateway if applicable

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #152136 · ✓ still in production