Fujian Snowman Group Co., Ltd. RefComp-SBC Series (Semi-hermetic Piston Compressor, Two-stage) — Industrial and commercial refrigeration; two-stage compression for low evaporating temperatures.

Components & Design

Component data being added…

Technical Data

power kW 12–30 HP (≈9–22 kW), 6 models
airflow m3h 27.6–51.5 m³/h (high-pressure displacement)
refrigerant R22, R404A, R507
max pressure bar 28

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Check valve plates and reed valves for wear, cracking, and deformation; replace at manufacturer-specified intervals

Check valve plates and reed valves for wear, cracking, and deformation; replace at manufacturer-specified intervals

Inspect crankcase oil level and oil quality; check for refrigerant dilution, contamination, and correct viscosity grade

Inspect crankcase oil level and oil quality; check for refrigerant dilution, contamination, and correct viscosity grade

Verify crankcase heater function before start-up to prevent liquid refrigerant slugging in the oil sump

Verify crankcase heater function before start-up to prevent liquid refrigerant slugging in the oil sump

Check suction and discharge pressure readings against design operating envelope; investigate any deviation in compression ratio

Check suction and discharge pressure readings against design operating envelope; investigate any deviation in compression ratio

Inspect shaft seals and gaskets for leaks; check all flanged connections and brazed joints with leak detector

Inspect shaft seals and gaskets for leaks; check all flanged connections and brazed joints with leak detector

Measure motor winding insulation resistance and check supply voltage/current balance across all three phases

Measure motor winding insulation resistance and check supply voltage/current balance across all three phases

Inspect suction filter/strainer and oil filter; clean or replace if differential pressure limit is exceeded

Inspect suction filter/strainer and oil filter; clean or replace if differential pressure limit is exceeded

Verify unloading solenoid valve operation and capacity-control steps; check for correct pressure differential across stages on two-stage models (SB/SBC series)

Verify unloading solenoid valve operation and capacity-control steps; check for correct pressure differential across stages on two-stage models (SB/SBC series)

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #151977 · ✓ still in production