BITZER SE

2MTE-5K

BITZER SE 2MTE-5K — ECOLINE transcritical CO₂ semi-hermetic reciprocating compressor; small transcritical CO₂ systems.

Components & Design

Component data being added…

Technical Data

cooling capacity kW 6.56
power kW 11.35
airflow m3h 3.3
weight kg 95
cylinders 2
refrigerant CO₂ (transcritical)

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Check oil level and oil quality; replace oil and oil filter per manufacturer schedule (typically every 1–2 years or after 10,000–20,000 operating hours)

Check oil level and oil quality; replace oil and oil filter per manufacturer schedule (typically every 1–2 years or after 10,000–20,000 operating hours)

Inspect and test suction and discharge valves for wear, damage, leakage, or carbon deposits; replace valve plates and seats as required

Inspect and test suction and discharge valves for wear, damage, leakage, or carbon deposits; replace valve plates and seats as required

Verify motor winding insulation resistance and check electrical connections, contactors, and motor protection (overload relays, PTC sensors, IQ module)

Verify motor winding insulation resistance and check electrical connections, contactors, and motor protection (overload relays, PTC sensors, IQ module)

Monitor and record suction/discharge pressures and temperatures against design parameters; verify superheat and subcooling values

Monitor and record suction/discharge pressures and temperatures against design parameters; verify superheat and subcooling values

Inspect shaft seal (open-drive models) for refrigerant and oil leaks; replace seal elements at recommended intervals

Inspect shaft seal (open-drive models) for refrigerant and oil leaks; replace seal elements at recommended intervals

Check crankcase heater operation to ensure oil temperature is above dew point before compressor start; verify heater resistance

Check crankcase heater operation to ensure oil temperature is above dew point before compressor start; verify heater resistance

Inspect and tighten all pipe connections, flanges, and mounting bolts; check vibration isolators and flexible connections for deterioration

Inspect and tighten all pipe connections, flanges, and mounting bolts; check vibration isolators and flexible connections for deterioration

Verify capacity control system operation (VARISTEP solenoid valves, unloaders, or variable speed drive); check for correct part-load staging and step activation

Verify capacity control system operation (VARISTEP solenoid valves, unloaders, or variable speed drive); check for correct part-load staging and step activation

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #151900 · ✓ still in production