DW 125
Svanehøj DW 125 — Product and chemical tankers, gas carriers, liquefied gas cargo.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Common failures & inspection points
Double mechanical shaft seal inspection - primary seal against cargo, secondary seal against lubricating oil
Stainless steel shaft and ball bearing arrangement condition assessment
Oil-filled drive shaft column and slide bearing lubrication and wear check
Discharge flange integrity and EN 1092 PN16 standard compliance verification
Pump head casting for cracks or defects and fastener tightness
Electrical motor - explosion-proof and weather-proof enclosure condition
Service interval adherence: first interval at 5,000-15,000 operating hours or 5-15 years for seal, bearing, gasket replacement
Shaft straightness and bearing condition check at second interval: 10,000-20,000 operating hours or 10-20 years
Type-general inspection and maintenance points for this equipment category — not model-specific.