Common failures & inspection points
Visual external inspection for corroded areas, abraded surfaces, dents, distortions, and defects in welds that might render valve unsafe
Pressure and leakage test (maintain test pressure minimum 5 minutes); check for any external moisture/drips; verify seat tightness after depressurization
Functional test: valve must open at required set pressure (±0% to +10%); reseat to leak-tight at minimum 90% of discharge pressure
Manual actuation test (if accessible) to verify smooth, free movement; inspect stem for corrosion, erosion, or damage preventing safe operation
Visual inspection of all visible gaskets and seals for cracks, hardening, deformation, shrinkage, or discoloration indicating thermal or chemical degradation
Type-general inspection and maintenance points for this equipment category — not model-specific.