"> Atlas Incinerators Atlas 1500 (1500 kW) SL WS P
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 3 verified suppliers & service companies for Atlas Incinerators in the Maritime Network Find suppliers →
Atlas Incinerators

Atlas 1500 (1500 kW) SL WS P

Atlas Incinerators Atlas 1500 (1500 kW) SL WS P — Marine incinerator for solid and liquid waste, large incinerator for very big merchant vessels.

Components & Design

Component data being added…

Technical Data

Power Rating 1500 kW (1,290,000 kcal/h)
Solid Waste Capacity 230 kg/h max (920 kg/24 hours)
Liquid Waste Capacity 129 l/h (0% water), 170 l/h (20% water), 258 l/h (50% water)
Waste Sluice Options 30L, 70L or 120L waste bag sluice
Dimensions (1500 SL B WS M) 2929 mm W x 3000 mm H x 4077 mm L

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Refractory lining deterioration and combustion chamber damage

Visual and structural inspection for cracks, erosion, corrosion in combustion chamber and refractory lining; assess condition for temperatures up to 1600°C withstand capability

Emissions exceed IMO MARPOL Annex VI limits (SOx, NOx, dioxins)

Test incinerator emissions to ensure they are within acceptable limits and comply with MARPOL Annex VI standards; verify combustion temperatures maintained at 850-950°C; check automated emission monitoring systems are operational

Burner malfunction, flame instability, or incomplete combustion

Test flame monitors, check burner nozzles for carbon buildup or damage; inspect fuel delivery system for leaks or blockages; verify fuel type and delivery rate; clean oil supply filters and burner components; test automatic ignition and flame failure protection systems

Flue gas system failures, leaks in exhaust line, or inadequate draft

Inspect all seals, gaskets, and connections in flue gas system for leaks; conduct smoke tests to verify proper exhaust of combustion gases; check three-chamber system integrity; verify flue gas temperature (850-1,200°C range); clean accumulated soot and ash from combustion and ash removal systems

Safety system failures (temperature control, pressure relief, shutdown systems)

Test all safety features including temperature controllers, pressure relief valves, flame monitors, and automatic shutdown systems for malfunction; verify interlock systems preventing unsafe operation; review all operational and maintenance records to confirm documented periodic maintenance is current

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet