Technical Data

Type Vertical single-stage double-suction upward opening
Discharge bore 350 mm
Model variant B-type variant

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Bearing lubrication degradation and overheating

Use infrared thermometer to measure bearing temperature. Normal operating temperature should not exceed 10-15°C above ambient. Overheating indicates wear, misalignment, or insufficient lubrication. Measure baseline regularly and monitor for increases.

Mechanical seal degradation and internal leakage

Inspect gland packing or mechanical seal for visible weeping/dripping (acceptable <5 drops/minute). Check pressure at seal cavity. Replace mechanical seal if leakage exceeds acceptable limits or if visual inspection shows seal face wear, scoring, or deposits. Verify seal installation orientation correct.

Vibration due to bearing wear, cavitation, or impeller imbalance

Use vibration meter to monitor pump vibration during operation. Record baseline at commissioning. Alert if vibration increases 25% from baseline in any axis. Imminent failure indicated by 50% increase. Compare against manufacturer specifications. High vibration can cause catastrophic bearing failure.

Impeller corrosion (saltwater/seawater applications) and erosion

Inspect impeller blade surfaces for erosion pitting, corrosion deposits, or material loss especially on suction side. Check for calcium/salt deposits buildup indicating seawater circulation. Ensure material compatibility with cooling medium (FW vs SW). Replace impeller if erosion >2mm depth observed.

Cavitation damage and performance loss

Monitor pressure at pump inlet (suction side). Ensure suction pressure remains above 0.3 bar absolute. Listen for characteristic noise signature (machine-gun-like sound). Check inlet filter/strainer condition - clean or replace if pressure drop >0.5 bar. Verify inlet line diameter adequate and free of restrictions.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #144607 · ✓ still in production