Silnik główny 4-suwowy · Silniki główne (4-suwowe)
The MAN Energy Solutions 9L48/60 is a medium‑speed, 9‑cylinder, four‑stroke diesel main engine delivering about 10 800 kW at 514 rpm, designed for flexible fuel use (MGO/HFO) and robust ship propulsion.
Masz kartę katalogową producenta dla tego modelu? Wyślij ją razem z formularzem zapytania — sprawdzimy ją i podamy źródło.
| Fuel Injectors (overhaul/renewal) | 3,000 - 6,000 hours |
|---|---|
| Exhaust Valves (inspection/overhaul) | 6,000 - 12,000 hours |
| Piston Overhaul (rings, liner inspection) | 12,000 - 18,000 hours |
| Fuel Pumps (overhaul/renewal of elements) | 6,000 - 12,000 hours |
| Turbocharger (minor overhaul) | 6,000 - 12,000 hours |
| Turbocharger (major overhaul) | 18,000 - 24,000 hours |
| Main & Crankpin Bearings (inspection) | 18,000 - 24,000 hours |
| Cylinder Liner Calibration | 12,000 - 18,000 hours |
| Safety Devices (functional test) | Annually / 5,000 hours |
| Cylinder Liner Bore Wear | Max 3.5 mm total ovality/taper from nominal bore (480mm). |
|---|---|
| Piston Ring Groove Clearance (Top Ring) | Max 0.20 - 0.30 mm. |
| Crankshaft Deflection | Max 0.05 - 0.10 mm (between adjacent main bearings). |
| Main/Crankpin Bearing Clearance | Max 0.20 - 0.30 mm over nominal clearance. |
| Exhaust Valve Seat Recession | Max 1.5 - 2.0 mm from nominal position. |
| Fuel Pump Plunger/Barrel Clearance | Max 0.01 - 0.02 mm. |
Zakresy są typowe dla tej klasy konstrukcyjnej. Decydujące są zawsze dokumenty producenta dla danego numeru seryjnego.
Class surveyors typically focus on: 1. Reviewing engine logbooks and trend analysis of critical parameters (EGTs, pressures, temperatures) to assess engine health. 2. Witnessing functional tests of all safety devices (overspeed trip, low lube oil pressure/high temperature shutdowns, oil mist detector). 3. Opening crankcase doors for visual inspection of main and crankpin bearings, connecting rod bolts, and general cleanliness. 4. Inspecting high-pressure fuel lines, leak-off arrangements, and ensuring compliance with fire safety regulations. 5. Checking the turbocharger's general condition, signs of fouling, and bearing integrity. 6. Verifying tightness of foundation bolts and absence of cracks/corrosion in the engine seating. 7. Reviewing maintenance records, spare parts inventory, and lube oil analysis reports. 8. General assessment of engine room cleanliness, absence of leaks, and proper securing of components.
Szacowana trwałość: 80,000 - 120,000 hours before major engine block/crankshaft overhaul, assuming diligent maintenance and component renewals.
Bezpłatnie — wyślij zapytanie dotyczące sprzętu MAN Energy Solutions. Nasz zespół je sprawdzi i odpowie e-mailem.
Inne modele tego samego typu sprzętu, najpierw MAN Energy Solutions.
Powiedz nam, czego potrzebujesz do tego MAN Energy Solutions 9LL48/60 — części, wizyty serwisowej, drugiej opinii. Czy jesteś MAN Energy Solutions? Przejmij tę stronę marki.
Serwisant? Napisz raport dzienny dla tego 9LL48/60 w OceanSphere Work — zdjęcia, godziny i części, jako PDF dla armatora. Wypróbuj 14 dni za darmo →
Tak. Dane techniczne, dokumenty i uwagi serwisowe tego modelu są dostępne bez konta. Konto dodaje zapisane wyszukiwania i zapytania, niczego nie odbiera.
Tak. Podaj producenta, model i czego potrzebujesz — każde zapytanie czyta człowiek i odpowiada e-mailem.
Wyślij nam tabliczkę lub prawidłową wartość. Sprawdzimy ją w karcie danych producenta lub rejestrze towarzystwa klasyfikacyjnego i zaktualizujemy stronę.