Biblioteka› Engine Room› Silniki główne (4-suwowe)› Silnik główny 4-suwowy› MAN Energy Solutions 18VV32/44CR

18VV32/44CR

Silnik główny 4-suwowy · Silniki główne (4-suwowe)

Dane techniczne ze źródeł producenta lub towarzystwa · jeszcze niesprawdzone ręcznie​‍​‍⁠‌‍‍​‌‍‍‌⁠⁠‌‍‌​‍
10 080 kWMoc
18Cylindry
320 mmŚrednica cylindra
440 mmSkok

The MAN Energy Solutions 18VV32/44CR is an 18‑cylinder V‑type medium‑speed diesel main engine delivering up to 10 080 kW at 750 rpm, featuring high‑pressure common‑rail fuel injection and Tier II emissions compliance.

Dane techniczne

Dane techniczne.dane referencyjne — niezweryfikowane

Masz kartę katalogową producenta dla tego modelu? Wyślij ją razem z formularzem zapytania — sprawdzimy ją i podamy źródło.

Bohrung x Hub320 mm x 440 mm
Hubraum pro Zylinder35,4 dm³
Leistung pro Zylinder (MCR, 750 rpm)600 kW (L-Reihe), 560 kW (V-Reihe)
MEP (Mean Effective Pressure)27,1 bar (Durchschnitt); L-Reihe: 29,4-29,9 bar
Mittlere Kolbengeschwindigkeit11 m/s
Spezifischer Treibstoffverbrauch (SFOC) @ 85% MCR172 g/kWh (L-Serie); 171 g/kWh (V-Serie)
Gewicht 6L32/44CR39,5 Tonnen
Gewicht 10L32/44CR58,0 Tonnen
Gewicht 12V32/44CR70 Tonnen
Gewicht 20V32/44CR104 Tonnen
Common Rail Druck1600 bar
EmissionsstandardsIMO Tier II (Serie); IMO Tier III mit SCR
Zylinderabstand (Twin Engine)2500 mm (L32/44); 4000 mm (V32/44)
KonfiguracjaV
Obroty (1/min)750
Rodzaj paliwaMGO/HFO
TechnologiaCommon Rail Tier II
Moc (kW)10080
Inspekcja

Szczegóły inspektora ✓ zweryfikowane

Typowe problemy

  • Turbocharger fouling by soot deposits on turbine blades and nozzle rings, leading to performance loss and increased exhaust back pressure.
  • Common Rail injector issues (clogging, leakage, poor atomization) due to HFO quality, high pressure operation, or thermal stress.
  • High-pressure fuel pump wear or failure (e.g., plunger seizure, seal degradation) impacting fuel delivery and pressure.
  • Cylinder liner scuffing or excessive wear, particularly under transient loads or with inadequate lubrication/fuel quality.
  • Exhaust valve burning or seat wear due to high combustion temperatures, HFO combustion by-products, or improper valve rotation.
  • Piston ring breakage or sticking, leading to increased blow-by, higher lube oil consumption, and potential liner damage.
  • Bearing wear (main and connecting rod) caused by lube oil degradation, contamination, or insufficient clearance.
  • Cooling system fouling (jacket water, charge air cooler) reducing heat transfer efficiency and leading to elevated temperatures.

Lista kontrolna przeglądu

  • Turbocharger: Inspect turbine and compressor sides for fouling, damage, and excessive bearing play (axial/radial). Check air filter condition and differential pressure.
  • Fuel System (Common Rail): Check for high-pressure fuel leaks, especially at connections and injectors. Monitor fuel filter differential pressure. Assess injector performance via exhaust gas temperature uniformity or specific diagnostic tools.
  • Lubricating Oil System: Verify oil pressure and temperature. Check lube oil filter differential pressure. Inspect sump oil level and condition. Review recent Lube Oil Analysis Reports for trends.
  • Cylinder Units: Conduct boroscope inspection of cylinder liners for scuffing, wear ridges, and piston crowns for deposits or burning. Monitor individual cylinder exhaust gas temperatures for deviations.
  • Valve Train: Check valve clearances (if adjustable) and inspect valve rotators for proper function. Listen for unusual noises during operation.
  • Cooling System: Verify jacket water pressure and temperature. Check expansion tank level and water treatment parameters. Inspect charge air cooler for external and internal fouling. Look for any signs of leaks.
  • Engine Foundation & Mountings: Visually inspect all engine foundation bolts for tightness and signs of movement. Check condition of anti-vibration mounts (if fitted).
  • Safety Devices: Functionally test engine overspeed trip, low lube oil pressure shutdown, and high cooling water temperature alarm/shutdown. Verify oil mist detector operation.

Interwały serwisowe

Fuel Filters (fine)500 - 1,000 hours
Lube Oil Filters500 - 1,000 hours
Lube Oil Analysis250 - 500 hours
Common Rail Injector Overhaul6,000 - 12,000 hours
Cylinder Head Overhaul (Valves, Seats)6,000 - 12,000 hours
Piston Overhaul (Rings, Skirt)12,000 - 24,000 hours
Turbocharger Overhaul12,000 - 24,000 hours
Connecting Rod Bearing Inspection12,000 - 24,000 hours
Major Overhaul (Main Bearings, Crankshaft Inspection)36,000 - 48,000 hours

Typowe granice zużycia

Cylinder Liner WearMax. 0.6 - 0.8 mm total wear (oval/taper) from original bore diameter (320 mm).
Piston Ring Axial ClearanceMax. 0.15 - 0.25 mm (depending on ring type and position).
Crankshaft DeflectionMax. 0.05 - 0.10 mm (total indicator reading between adjacent webs).
Main/Connecting Rod Bearing ClearanceMax. 0.15 - 0.25 mm (measured with lead wire or plastigauge).
Exhaust Valve Seat RecessionMax. 0.5 - 1.0 mm (from original position, requiring reconditioning or replacement).
Turbocharger Rotor Axial PlayMax. 0.15 - 0.25 mm (check manufacturer's specific data).
Turbocharger Rotor Radial PlayMax. 0.25 - 0.40 mm (check manufacturer's specific data).

Zakresy są typowe dla tej klasy konstrukcyjnej. Decydujące są zawsze dokumenty producenta dla danego numeru seryjnego.

Krytyczne części zamienne

  • Common Rail Injectors (at least 1-2 per cylinder type, e.g., 18VV32/44CR would need 1-2 sets of 18 injectors)
  • High-pressure fuel pump elements or complete repair kit
  • Complete set of fuel filters (primary, secondary, fine) for all stages
  • Complete set of lubricating oil filters
  • Piston rings (at least one complete set per cylinder, i.e., 18 sets)
  • Exhaust and Inlet Valves with seats/guides (at least one set per cylinder)
  • Turbocharger bearing cartridge or complete repair kit
  • Assorted O-rings, gaskets, and seals for common maintenance tasks (e.g., cylinder head, fuel system)

Bezpieczeństwo

  • High-Pressure Fuel Leaks: Common Rail systems operate at extreme pressures (up to 2000+ bar). Leaks can atomize fuel, creating an invisible, highly flammable mist that can auto-ignite on hot surfaces, leading to severe engine room fires.
  • Crankcase Explosions: Caused by localized overheating (e.g., bearing failure, piston seizure) leading to ignition of oil mist. Requires functional oil mist detectors and strict adherence to crankcase entry procedures.
  • Overspeed: Malfunction of the governor or engine safety system can lead to uncontrolled engine speed, resulting in catastrophic mechanical failure and potential projectile hazards.
  • Hot Surfaces & Exhaust Gas Leaks: Engine components, exhaust piping, and turbocharger operate at very high temperatures, posing severe burn risks. Exhaust gas leaks contain toxic components (CO, NOx) and can cause asphyxiation or fire.
  • Rotating Machinery: Exposed rotating components such as the flywheel, shaft couplings, and turbocharger rotor pose entanglement hazards. Ensure all guards are in place during operation.

Przegląd klasyfikacyjny

A class surveyor will typically focus on: 1. Documentation Review: Verification of engine logbooks, maintenance records, lube oil analysis reports, and spare parts inventory to ensure compliance with planned maintenance systems. 2. Performance Verification: Witnessing engine operation at various loads, checking power output, fuel consumption, exhaust gas temperatures, and pressures against design parameters and previous records. 3. Safety Device Testing: Functional testing of critical safety devices including overspeed trip, low lube oil pressure shutdown, high cooling water temperature shutdown, and oil mist detector alarms. 4. Crankcase Inspection: Opening of crankcase doors for visual inspection of main and connecting rod bearings, crankshaft, and general cleanliness. Assessment of oil mist detector functionality. 5. Cylinder Unit Inspection: Boroscope inspection of cylinder liners, piston crowns, and exhaust valves for wear, scuffing, deposits, and signs of burning. Measurement of cylinder liner wear may be required. 6. Fuel System Integrity: Thorough inspection for fuel leaks (especially high-pressure lines), filter condition, and overall system cleanliness and integrity. 7. Exhaust System Integrity: Inspection of exhaust manifold, turbocharger, and associated piping for leaks, cracks, and insulation condition. 8. Engine Foundation: Visual inspection of engine mounting bolts and chocking arrangements for tightness, corrosion, and integrity. 9. Vibration Monitoring: Assessment of engine vibration levels during operation to detect potential issues with balance or alignment.

Szacowana trwałość: 36,000 - 48,000 hours before major overhaul (e.g., main bearing renewal, crankshaft inspection). Total engine lifetime with proper maintenance and multiple overhauls can exceed 100,000 hours.

Potrzebujesz tej części?

Zapytaj o ofertę na ten model.

Bezpłatnie — wyślij zapytanie dotyczące sprzętu MAN Energy Solutions. Nasz zespół je sprawdzi i odpowie e-mailem.

W przypadku sprzętu okrętowego prawie żaden producent ani autoryzowany dystrybutor nie podaje ceny, dopóki statek jest nieznany. Z danymi statku dostępność i cenę da się ustalić szybciej; bez nich być może musimy najpierw dopytać, co kosztuje kilka dni. Jeśli nie wolno Ci podać statku, wystarczy zdjęcie tabliczki znamionowej — dołącz je poniżej lub odeślij w odpowiedzi na nasz e-mail potwierdzający.

Twoje dane kontaktowe nie są publikowane. Konto nie jest wymagane.
Powiązane modeli

Także w Silnik główny 4-suwowy.

Inne modele tego samego typu sprzętu, najpierw MAN Energy Solutions.

Według producenta MAN Energy SolutionsWärtsiläCaterpillarHiMSENMTUVolvo PentaYanmar Power Technology Co., Ltd.HanshinDaihatsuPielstickMaK (Caterpillar)Rolls-Royce / BergenCaterpillar MaKCumminsBaudouinWszyscy producenciCzęści według urządzeńNowy użytkownik? Załóż darmowe konto Nieczytelna tabliczka? Wypróbuj skaner tabliczek Wszystkie modele MAN Energy Solutions Podobne do 18VV32/44CR
Więcej, niż pokazuje karta katalogowa

Odpowiadamy e-mailem, nigdy automatem.

Powiedz nam, czego potrzebujesz do tego MAN Energy Solutions 18VV32/44CR — części, wizyty serwisowej, drugiej opinii. Czy jesteś MAN Energy Solutions? Przejmij tę stronę marki.

Serwisant? Napisz raport dzienny dla tego 18VV32/44CR w OceanSphere Work — zdjęcia, godziny i części, jako PDF dla armatora. Wypróbuj 14 dni za darmo →

Często pytane

Pytania, które pojawiają się przy tym sprzęcie.

Czy dane tego modelu są bezpłatne?

Tak. Dane techniczne, dokumenty i uwagi serwisowe tego modelu są dostępne bez konta. Konto dodaje zapisane wyszukiwania i zapytania, niczego nie odbiera.

Czy znajdziecie część dokładnie do tego modelu?

Tak. Podaj producenta, model i czego potrzebujesz — każde zapytanie czyta człowiek i odpowiada e-mailem.

Dane techniczne wydają się błędne — co teraz?

Wyślij nam tabliczkę lub prawidłową wartość. Sprawdzimy ją w karcie danych producenta lub rejestrze towarzystwa klasyfikacyjnego i zaktualizujemy stronę.