Regular maintenance and monitoring are crucial for ensuring the reliable operation of marine engines. The Wärtsilä 6W20DF is a dual-fuel engine designed to operate on both liquefied natural gas (LNG) and marine gas oil (MGO). This six-cylinder, in-line engine boasts a power output of 1170 kW at 900 rpm. Its key specifications include a bore of 200 mm, a stroke of 280 mm, and a compression ratio of 15:1. The engine's fuel-efficient design achieves a specific fuel oil consumption (SFOC) of 186-187 g/kWh under ISO conditions. The Wärtsilä 6W20DF is part of the W20DF family, which has seen over 6000 units delivered since its introduction in 2011.

Dane techniczne

Dane techniczne.dane referencyjne — niezweryfikowane

Masz kartę katalogową producenta dla tego modelu? Wyślij ją razem z formularzem zapytania — sprawdzimy ją i podamy źródło.

Bohrung × Hub200 × 280 mm
Hubraum pro Zylinder8,8 l
Leistung pro Zylinder (aktuell)185-220 kW (abhängig von Variante/Drehzahl)
Verdichtungsverhältnis15:1
Spezifischer Brennstoffverbrauch (SFOC)186-187 g/kWh (ISO-Bedingungen)
Motorkonfigurationen4L20, 5L20, 6L20, 8L20, 9L20 (nur Reihe)
Gewichte (Reihe-Motor)4L20: 6,8 t | 6L20: 8,3 t | 8L20: 10,5 t | 9L20: 11,1 t
Gewichte (Stromerzeuger)4L20: 14,0 t | 6L20: 16,8 t | 8L20: 20,7 t | 9L20: 23,8 t
Kolben-Mittenfluß-Geschwindigkeit8,4 m/s (900 rpm), 9,3 m/s (1000 rpm)
Ventile pro Zylinder2 Einlass + 2 Auslass
Konfiguracja4-Takt, nicht-umkehrbar, turbogela­den & Ladeluftkühlung, Direkteinspritzung
Ausführungen verfügbarDiesel (W20) & Dual-Fuel (W20DF, seit 2011)
Liefermenge seit 1990er>7500 Motoren insgesamt; >6000 W20DF-Einheiten
KonfiguracjaL
Obroty (1/min)900
Rodzaj paliwaDual-Fuel LNG/MGO
TechnologiaDual-Fuel
Moc (kW)1170
Inspekcja

Szczegóły inspektora

Typowe problemy

  • Balance shaft bearing damage – as identified, this is a critical failure point leading to significant secondary damage and downtime. Regular monitoring of vibration and lube oil analysis is crucial.
  • Gas valve unit (GVU) leaks or malfunction – common in DF engines, leading to gas leakage, misfiring, or inability to switch to gas mode. Requires precise calibration and seal integrity.
  • Fuel injector nozzle clogging or wear (both MDO/HFO and pilot fuel) – impacts combustion efficiency, increases exhaust temperatures, and can lead to cylinder overload or misfiring.
  • Turbocharger fouling or bearing wear – reduced engine efficiency, increased exhaust back pressure, and potential for catastrophic failure if bearings are neglected.
  • Cylinder liner wear and scuffing – especially critical with varying fuel qualities (HFO/MDO/LNG) and load profiles. Can lead to blow-by and increased lube oil consumption.
  • Piston ring sticking or breakage – often a consequence of poor combustion, inadequate lubrication, or liner wear, leading to loss of compression and power.
  • Main and connecting rod bearing wear – usually detected through lube oil analysis (wear metals) or increased crankshaft deflection. Can lead to crankshaft damage if neglected.

Lista kontrolna przeglądu

  • Balance Shaft Inspection: Visually check for any signs of oil leakage around the balance shaft housing. Listen for unusual noises (knocking, grinding) from the balance shaft area during operation. Review lube oil analysis for elevated copper/lead/tin levels indicating bearing wear.
  • Gas Train & Leak Detection: Verify the integrity of all gas piping, valves, and connections for leaks using appropriate sniffers or leak detection spray. Confirm functionality of the engine room gas detection system and its alarm/shutdown logic.
  • Fuel Injector Performance: Monitor exhaust gas temperatures (EGTs) for individual cylinders to identify imbalances. Check for fuel leakage at injector connections. For MDO/HFO injectors, inspect spray patterns if possible during maintenance, and verify cooling.
  • Turbocharger Condition: Inspect compressor and turbine sides for fouling, damage, or blade erosion. Check turbocharger bearing play (axial and radial) if accessible. Monitor boost pressure and exhaust gas differential pressure across the turbine.
  • Crankcase Breather & Pressure: Check crankcase pressure for abnormal readings, which can indicate excessive blow-by from worn piston rings or liners. Inspect the crankcase breather system for blockages or oil carry-over.
  • Lube Oil System: Verify lube oil pressure and temperature are within limits. Take samples for analysis (wear metals, TBN, viscosity, water content). Inspect filters for contamination.
  • Cooling Water System: Check cooling water temperatures and pressures (HT & LT circuits). Inspect heat exchangers for fouling and leaks. Verify proper operation of thermostatic valves.
  • Engine Mounts & Foundations: Inspect engine mounting bolts for tightness and signs of corrosion. Check resilient mounts for degradation or excessive compression, which can lead to increased vibration.

Interwały serwisowe

Lube Oil & Filters500 - 1000 running hours (depending on oil type and analysis)
Fuel Filters250 - 500 running hours (depending on fuel quality)
Cylinder Head Overhaul12,000 - 18,000 running hours (inspect valves, seats, springs, injectors)
Piston Overhaul (incl. rings)24,000 - 36,000 running hours (inspect piston crown, skirt, ring grooves)
Connecting Rod Bearings24,000 - 36,000 running hours (inspection/renewal)
Main Bearings48,000 - 60,000 running hours (inspection/renewal)
Turbocharger Overhaul12,000 - 24,000 running hours (minor), 36,000 - 48,000 running hours (major)
Balance Shaft Bearings24,000 - 36,000 running hours (inspection/renewal, given known issues)

Typowe interwały dla tej klasy konstrukcji, nie dane producenta dla Twojego modelu. Wiążąca jest instrukcja producenta.

Typowe granice zużycia

Cylinder Liner Wear (max)0.6 - 0.8 mm (measured at top ring TDC position)
Piston Ring Groove Wear (max)0.15 - 0.25 mm (increase in axial clearance)
Crankshaft Deflection (max for 6-cyl)0.05 - 0.08 mm (between adjacent main bearings)
Main Bearing Clearance (max)0.18 - 0.25 mm (new: 0.12-0.15 mm)
Connecting Rod Bearing Clearance (max)0.15 - 0.22 mm (new: 0.08-0.12 mm)
Turbocharger Rotor Axial Play (max)0.15 - 0.20 mm
Turbocharger Rotor Radial Play (max)0.30 - 0.40 mm

Zakresy są typowe dla tej klasy konstrukcyjnej. Decydujące są zawsze dokumenty producenta dla danego numeru seryjnego.

Krytyczne części zamienne

  • Fuel Injector Nozzles (MDO/HFO & Pilot Fuel)
  • Complete Gasket & O-ring Kits (for cylinder heads, fuel system, gas system)
  • Lube Oil, Fuel, and Air Filters (full sets)
  • Balance Shaft Bearings (complete set, given known failure mode)
  • Main and Connecting Rod Bearing Shells (at least one set)
  • Various Sensors (temperature, pressure, speed, gas detection)
  • High-Pressure Fuel Pump Elements / Gas Valve Actuators
  • Piston Rings (at least one cylinder set)

Bezpieczeństwo

  • LNG Leakage & Fire/Explosion Risk: The primary concern for DF engines. Ensure gas detection systems are fully operational, ventilation is adequate, and emergency shutdown systems (ESD) for gas supply are tested regularly.
  • High-Pressure Gas System Integrity: Inspect all high-pressure gas lines, fittings, and components for signs of damage, corrosion, or leaks. Adhere strictly to maintenance schedules for gas system components.
  • Emergency Shutdown Systems: Verify the functionality of all engine and fuel system emergency shutdowns, including overspeed, low lube oil pressure, high cooling water temperature, and gas leak alarms.
  • Hot Surfaces & Rotating Machinery: Standard engine room hazards. Ensure guards are in place for rotating parts and insulation is intact on hot surfaces (exhaust manifold, turbocharger).
  • Fuel Changeover Procedures: Ensure crew competency and strict adherence to procedures for switching between LNG, MDO, and HFO to prevent fuel mixing, pressure surges, or engine instability.

Przegląd klasyfikacyjny

For a Wärtsilä 6W20DF, class surveyors will typically focus on: 1. Documentation: Verification of all maintenance records, service reports, lube oil analysis trends, and compliance with manufacturer's recommendations. Review of statutory certificates (IAPP, IEE, IGF Code compliance). 2. Operational Tests: Witnessing engine start/stop procedures, emergency shutdown tests (overspeed, low oil pressure, high temp, gas leak), and fuel changeover functionality (LNG to MDO/HFO and vice-versa). Checking alarm and safety system functionality. 3. Gas System Integrity (IGF Code): Thorough inspection of the entire gas fuel supply system, including gas valve units (GVUs), double-wall piping, ventilation arrangements, gas detection systems, and inerting systems. Verification of pressure testing records for gas lines. 4. Crankcase Inspection: Opening of crankcase doors for visual inspection of main and connecting rod bearings, crankshaft, and balance shaft for signs of wear, overheating, or damage. Checking crankshaft deflection readings. 5. Cylinder Head & Piston Inspection: Depending on survey cycle, opening of selected cylinder heads for inspection of valves, seats, and injectors. Piston crown and ring inspection if due for overhaul. 6. Turbocharger & Exhaust System: Inspection of turbocharger for integrity, exhaust gas piping for leaks, and insulation condition. Checking exhaust gas economizer/boiler for cleanliness and leaks. 7. Engine Foundations & Mounts: Inspection of engine seating, chocking, and resilient mounts for integrity, corrosion, and proper securing. 8. Auxiliary Systems: Verification of lube oil, fuel oil, cooling water, and starting air systems, including pumps, filters, coolers, and associated piping for leaks and proper operation. 9. Fire Safety: Inspection of fire detection and extinguishing systems in the engine room and gas fuel handling areas, including fixed fire-fighting installations and portable equipment.

Szacowana trwałość: 80,000 - 120,000 running hours before major overhaul or rebuild, assuming diligent maintenance and operation within manufacturer's guidelines.

Potrzebujesz tej części?

Zapytaj o ofertę na ten model.

Bezpłatnie — wyślij zapytanie dotyczące sprzętu Wärtsilä. Nasz zespół je sprawdzi i odpowie e-mailem.

W przypadku sprzętu okrętowego prawie żaden producent ani autoryzowany dystrybutor nie podaje ceny, dopóki statek jest nieznany. Z danymi statku dostępność i cenę da się ustalić szybciej; bez nich być może musimy najpierw dopytać, co kosztuje kilka dni. Jeśli nie wolno Ci podać statku, wystarczy zdjęcie tabliczki znamionowej — dołącz je poniżej lub odeślij w odpowiedzi na nasz e-mail potwierdzający.

Twoje dane kontaktowe nie są publikowane. Konto nie jest wymagane.
Powiązane modeli

Także w Silnik główny 4-suwowy.

Inne modele tego samego typu sprzętu, najpierw Wärtsilä.

Według producenta MAN Energy SolutionsWärtsiläCaterpillarHiMSENMTUVolvo PentaYanmar Power Technology Co., Ltd.HanshinDaihatsuPielstickMaK (Caterpillar)Rolls-Royce / BergenCaterpillar MaKCumminsBaudouinWszyscy producenciCzęści według urządzeńNowy użytkownik? Załóż darmowe konto Nieczytelna tabliczka? Wypróbuj skaner tabliczek Wszystkie modele Wärtsilä Podobne do 6W20DF
Więcej, niż pokazuje karta katalogowa

Odpowiadamy e-mailem, nigdy automatem.

Powiedz nam, czego potrzebujesz do tego Wärtsilä 6W20DF — części, wizyty serwisowej, drugiej opinii. Czy jesteś Wärtsilä? Przejmij tę stronę marki.

Serwisant? Napisz raport dzienny dla tego 6W20DF w OceanSphere Work — zdjęcia, godziny i części, jako PDF dla armatora. Wypróbuj 14 dni za darmo →

Często pytane

Pytania, które pojawiają się przy tym sprzęcie.

Czy dane tego modelu są bezpłatne?

Tak. Dane techniczne, dokumenty i uwagi serwisowe tego modelu są dostępne bez konta. Konto dodaje zapisane wyszukiwania i zapytania, niczego nie odbiera.

Czy znajdziecie część dokładnie do tego modelu?

Tak. Podaj producenta, model i czego potrzebujesz — każde zapytanie czyta człowiek i odpowiada e-mailem.

Dane techniczne wydają się błędne — co teraz?

Wyślij nam tabliczkę lub prawidłową wartość. Sprawdzimy ją w karcie danych producenta lub rejestrze towarzystwa klasyfikacyjnego i zaktualizujemy stronę.