An addressable fire detection panel from Scana Mar-El that monitors detectors and activates alarms, fully compliant with SOLAS requirements; its defining feature is a networked architecture that identifies each detector individually. The supplied category identifies the equipment as Addressable Fire Detection Panel, and it is normally installed in the protected space, on the person, or at a fixed sensor point with signals returned to the relevant alarm or monitoring system. In that listed role, its primary purpose is to detect hazardous gas, oxygen condition, fire indication or another safety-related condition identified by the listed category. Fixed, portable, optical, heat, gas and oil-mist sensors use different principles, so calibration and functional testing must match the actual detector type. The model designation identifies the listed configuration, but no additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. The source metadata also states capacity: up to 1000 points. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

up to 1000 points
Capacity
Fire Suppression / Detection
Medium

Components & Design

Component data being added…

Technical Data

type addressable
solas True
origin Norway

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Sensor ageing, poisoning, contamination or dirt causes drift, slow response, false alarms or failed tests
Power, battery, wiring or communication faults cause device-failure alarms or loss of indication
Water ingress, corrosion or impact damage causes intermittent operation or failed controls
Blocked sampling paths or obstructed detector exposure delays response or prevents correct detection
Incorrect calibration, configuration or detector type causes misleading readings or nuisance alarms

Service & Maintenance

Inspect sensors, sample paths or detector openings, wiring, power, mounting and alarm interfaces. Perform bump tests, functional tests or calibration using the approved method for the device type. Review alarm history and confirm remote indications or shutdown interfaces. Refer to the manufacturer documentation for the exact figure for calibration and alarm criteria.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry detector heads or sensor cartridges, filters, sampling parts, batteries or chargers, fuses, calibration accessories and approved test consumables.
Equipment Model #1426 · ✓ still in production