Esser / Honeywell

Esser 32L×254D-C

Esser / Honeywell Esser 32L×254D-C is a shipboard unit in the Fire Detection Systems group, classified in the source as Addressable Fire Detection Panel. It is normally installed in fire-control stations, bridge or safety centers, with detectors and loops distributed through accommodation, machinery and service spaces. Its primary duty is to detect fire signatures, identify the affected zone and initiate alarms or related safety functions. In service it interfaces with smoke/heat/flame detectors, loops, manual call points, sounders, remote panels, shutdowns, dampers and vessel alarm systems. Compared with neighboring entries in the same product family, this record is the exact Esser / Honeywell Esser 32L×254D-C variant; the model designation should be retained unchanged when matching onboard documentation and spares. For exact limits, settings, test values and approved maintenance criteria, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

loops 32
devices per loop 254
addressable True
imo compliant True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Detector contamination or ageing, typically indicated by false alarms, reduced sensitivity or detector fault indication
Loop wiring open/short circuit from cable or terminal damage, typically indicated by zone/loop fault alarms and loss of multiple devices
Power-supply or backup-battery failure, typically indicated by panel power alarms or loss of standby capability
Addressable module or panel electronics fault, typically indicated by missing devices, communication errors or unstable indications
Incorrect detector placement/obstruction or damaged sensing path, typically indicated by slow or unreliable detection during testing

Service & Maintenance

Inspect panel status, loop integrity, detector cleanliness and accessibility, manual call points, sounders, backup supply, shutdown interfaces and alarm history; perform detector and cause/effect testing under the vessel's approved fire plan.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep compatible detectors, bases, loop isolators/modules, fuses, backup batteries where applicable, sounders and critical panel power-supply components.
Equipment Model #140771 · ✓ still in production