Danfoss Semco

Semco CO2 2000kg

Danfoss Semco Semco CO2 2000kg is listed as a marine co2 fixed fire system in the Fixed Fire Suppression / CO2 Fixed Fire System category. Equipment of this class is typically installed in the protected machinery, accommodation, cargo, deck, or service area with control equipment located at designated fire stations or safety spaces. Its shipboard purpose is to detect, alarm, contain, or suppress a shipboard fire according to the system's approved fire-safety function. The exact piping, electrical, control, foundation, and accessory arrangement depends on the vessel and the supplied configuration. No additional verified rating, capacity, weight, dimension, or other model-specific figure is supplied in the structured source data. Any differences from adjacent models in the same family, including rating, size, material, control, certification, or accessory differences not explicitly listed here, should be confirmed in the manufacturer documentation.

Components & Design

Component data being added…

Technical Data

charge kg 2000

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Blocked, damaged, corroded, or contaminated detectors, nozzles, piping, valves, or release components reduce coverage or prevent correct discharge
Loss of extinguishing medium, pressure, water supply, or foam concentrate causes low-level indications, failed tests, or reduced firefighting capability
Control-panel, power-supply, loop, cable, or communication faults produce alarms, disabled zones, or loss of remote release
Valve, damper, actuator, or interlock faults prevent the required shutdown, isolation, or agent release sequence
Poor maintenance, incorrect line-up, or obstructed access is identified during tests and can delay emergency response

Service & Maintenance

Inspect control panels, supplies, detectors or nozzles, valves, piping, alarms, remote releases, shutdown interlocks, signage, access, and system status. Functional testing, agent quantities, pressure settings, detector spacing, and discharge criteria must follow SOLAS, class, flag, approved fire-control plans, and manufacturer documentation.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry approved detector or call-point units, fuses, seals and gaskets, valve or actuator service parts, nozzles or sprinkler heads where applicable, and critical control modules recommended for the installed system.
Equipment Model #130171 · ✓ still in production