Trane Marine

RTAC Split 50kW R134a

Trane Marine RTAC Split 50kW R134a is listed in the source as a marine Split AC Unit within the Air Conditioning group. Equipment of this type is typically installed in accommodation, machinery or service spaces, with air-handling components located in ventilation rooms, ducts or local compartments according to the vessel layout. Its primary duty is ventilation, heating, cooling or air circulation associated with the Split AC Unit, and it uses fans, coils or refrigerant components where fitted, filters, dampers and controls to maintain airflow and the required space condition. Neighboring variants can differ in rating, size, interface, approval basis or arrangement, so the complete model designation and actual nameplate data are important for identification. It normally interfaces with ship electrical power, ventilation ducting, chilled or hot water or refrigerant circuits where fitted, drains, dampers and automation controls. For any exact capacity, pressure, voltage, tolerance, wear limit or setting not stated in the source, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

cooling capacity kw 50
heating capacity kw 40.0
refrigerant R134a
air flow m3h 7500

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Filter blockage or coil fouling caused by dust, salt or poor cleaning can reduce airflow and cause poor heating or cooling performance
Fan, motor or bearing wear caused by imbalance, contamination or ageing can produce vibration, noise or loss of airflow
Control sensor or actuator faults caused by wiring problems, drift or failed dampers can cause unstable temperature, incorrect airflow or persistent alarms
Drain blockage or condensate leakage caused by dirt or poor fall can produce water accumulation, corrosion or leakage into adjacent spaces
Refrigerant or water-side leakage where applicable caused by damaged joints, coils or seals can lead to reduced capacity, low-pressure alarms or visible fluid loss

Service & Maintenance

Inspect filters, coils, fans, bearings, drains, dampers, insulation and controls. Confirm airflow is unobstructed and compare temperature or pressure indications with normal vessel trends rather than relying on a single reading. Refer to manufacturer documentation for exact refrigerant, airflow and service values.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Typical spares include filters, belts where fitted, fan bearings or motor parts, control sensors, actuators, drain components, contactors and approved sealing items for the relevant heating or cooling circuit.