FWN Self-Contained 20kW R134a
Daikin Marine FWN Self-Contained 20kW R134a — Air Conditioning.
Inspector Detail
▸
Common issues
- Refrigerant leakage at flare or braze joints over time, reducing cooling capacity
- Condenser fouling (seawater-cooled) from scale or marine growth, reducing heat rejection
- Compressor short-cycling from low refrigerant charge or faulty pressure switches
- Evaporator coil icing from low airflow or low refrigerant charge
- Seawater pump or strainer blockage reducing condenser cooling water flow
- Control board or thermostat sensor failure causing erratic operation
- Fan motor bearing wear increasing noise and reducing airflow
Inspection checklist
- Check refrigerant pressures against the maker's expected range for ambient/seawater temperature
- Inspect joints for oil staining indicating refrigerant leaks
- Check seawater strainer for blockage and condenser for scaling/fouling
- Verify condensate drain is clear and draining correctly
- Check compressor mounting, vibration isolators, and electrical connections
- Test high/low pressure safety switches and any freeze protection
- Check fan motor bearing noise and airflow across the evaporator
- Verify control panel alarms and thermostat calibration
Service intervals
| Seawater strainer cleaning | weekly to monthly depending on water quality |
| Condenser cleaning (chemical/mechanical) | 6-12 months depending on fouling rate |
| Refrigerant leak check | annually |
| Filter/evaporator coil cleaning | every 1-3 months depending on air quality |
| Compressor oil/refrigerant charge verification | annually |
Critical spares
- R134a refrigerant charge
- Compressor contactor/start relay
- High/low pressure switch
- Seawater pump seal kit
Safety
- Refrigerant under pressure - use proper recovery equipment, never vent to atmosphere
- Electrical hazard at compressor terminals - isolate before opening
- Seawater system under pressure - isolate before opening the strainer or pump
Class survey
HVAC units are not typically a dedicated class survey item unless tied to accommodation ventilation/fire-damper arrangements or serving safety-critical spaces such as the engine control room; surveyor interest is usually limited to fire damper integrity where ducting penetrates fire divisions.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →