Daikin Marine

FWN Self-Contained 20kW R134a

Daikin Marine FWN Self-Contained 20kW R134a — Air Conditioning.

Inspector Detail

Common issues

  • Refrigerant leakage at flare or braze joints over time, reducing cooling capacity
  • Condenser fouling (seawater-cooled) from scale or marine growth, reducing heat rejection
  • Compressor short-cycling from low refrigerant charge or faulty pressure switches
  • Evaporator coil icing from low airflow or low refrigerant charge
  • Seawater pump or strainer blockage reducing condenser cooling water flow
  • Control board or thermostat sensor failure causing erratic operation
  • Fan motor bearing wear increasing noise and reducing airflow

Inspection checklist

  • Check refrigerant pressures against the maker's expected range for ambient/seawater temperature
  • Inspect joints for oil staining indicating refrigerant leaks
  • Check seawater strainer for blockage and condenser for scaling/fouling
  • Verify condensate drain is clear and draining correctly
  • Check compressor mounting, vibration isolators, and electrical connections
  • Test high/low pressure safety switches and any freeze protection
  • Check fan motor bearing noise and airflow across the evaporator
  • Verify control panel alarms and thermostat calibration

Service intervals

Seawater strainer cleaning weekly to monthly depending on water quality
Condenser cleaning (chemical/mechanical) 6-12 months depending on fouling rate
Refrigerant leak check annually
Filter/evaporator coil cleaning every 1-3 months depending on air quality
Compressor oil/refrigerant charge verification annually

Critical spares

  • R134a refrigerant charge
  • Compressor contactor/start relay
  • High/low pressure switch
  • Seawater pump seal kit

Safety

  • Refrigerant under pressure - use proper recovery equipment, never vent to atmosphere
  • Electrical hazard at compressor terminals - isolate before opening
  • Seawater system under pressure - isolate before opening the strainer or pump

Class survey

HVAC units are not typically a dedicated class survey item unless tied to accommodation ventilation/fire-damper arrangements or serving safety-critical spaces such as the engine control room; surveyor interest is usually limited to fire damper integrity where ducting penetrates fire divisions.

Estimated lifetime: Self-contained marine AC units of this class typically give 10-15 years of service with compressor and condenser maintenance, subject to seawater cooling water quality - confirm against maker's manual

Components & Design

Component data being added…

Technical Data

cooling capacity kw 20
heating capacity kw 16.0
refrigerant R134a
air flow m3h 3000

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #108327 · ✓ still in production