"> Bronswerk Marine BAC Air 10kW R410A
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 1 verified suppliers & service companies for Bronswerk Marine in the Maritime Network Find suppliers →
Bronswerk Marine

BAC Air 10kW R410A

Bronswerk Marine BAC Air 10kW R410A — Air Conditioning. The supplied category identifies the equipment as Air Handling Unit, and it is normally installed in an accommodation, machinery or technical HVAC space connected to ductwork, refrigerant, chilled water, heating or electrical services as applicable. In that listed role, its primary purpose is to move, cool, heat, filter or condition air for occupied and technical ship spaces. Split units, air-handling units, fan coils, chillers and ventilation fans differ in refrigeration and air-distribution arrangement, so the installed configuration determines the service points. The model designation identifies the listed configuration, but no additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

cooling capacity kw 10
heating capacity kw 8.0
refrigerant R410A
air flow m3h 1500

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Dirty filters, coils or air paths reduce airflow and cause poor temperature control or fan overload
Fan, motor, belt or bearing wear causes vibration, abnormal noise or reduced airflow
Refrigerant, chilled-water or heating-circuit leakage causes loss of cooling or heating capacity
Condensate drain blockage causes water leakage, corrosion or biological growth
Sensor, thermostat, damper or control faults cause unstable temperature, incorrect airflow or repeated trips

Service & Maintenance

Inspect filters, fans, bearings, belts or couplings, coils, refrigerant or water connections, dampers, condensate drains and controls. Clean heat-transfer surfaces and drains and check for corrosion, leakage and vibration. Verify temperature and airflow sensors against the approved control scheme. Refer to the manufacturer documentation for the exact figure for refrigerant charge, airflow and control settings.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry filters, belts, fan bearings or motors, actuator parts, temperature sensors, drain components, refrigeration service items, fuses and control relays.
Equipment Model #107682 · ✓ still in production