Daikin Marine

ZRQ Chiller 100kW R410A

Daikin Marine ZRQ Chiller 100kW R410A is listed as a marine air-conditioning unit in the Air Conditioning / Chiller Unit category. Equipment of this class is typically installed in an HVAC machinery space, accommodation area, technical room, or local split-system installation serving the conditioned space. Its shipboard purpose is to remove heat and moisture from occupied or technical spaces and maintain controlled temperature and humidity. The exact piping, electrical, control, foundation, and accessory arrangement depends on the vessel and the supplied configuration. No additional verified rating, capacity, weight, dimension, or other model-specific figure is supplied in the structured source data. Any differences from adjacent models in the same family, including rating, size, material, control, certification, or accessory differences not explicitly listed here, should be confirmed in the manufacturer documentation.

Components & Design

Component data being added…

Technical Data

cooling capacity kw 100
heating capacity kw 80.0
refrigerant R410A
air flow m3h 15000

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Refrigerant leakage from joints, seals, hoses, or heat exchangers causes poor cooling and abnormal suction or discharge conditions
Condenser fouling or restricted cooling-air or cooling-water flow raises condensing temperature and can cause high-pressure trips
Evaporator or air-filter fouling reduces heat transfer and produces low airflow, icing, or poor room cooling
Compressor wear, lubrication problems, or electrical faults cause noise, overheating, reduced capacity, or protective trips
Thermostat, sensor, expansion device, fan, or control-board faults cause unstable temperature, short cycling, or failed automatic operation

Service & Maintenance

Check refrigerant circuit condition, compressor, condenser, evaporator, filters, fans, drains, insulation, temperature sensors, safety trips, and control history. Clean heat-transfer surfaces and verify cooling-water or airflow condition; refrigerant charging and exact pressure or temperature settings must follow manufacturer documentation.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Typical spares include filters, fan or motor items, contactors and fuses, temperature sensors, drain components, approved refrigerant-circuit seals, and model-specific control or compressor service parts.
Equipment Model #106582 · ✓ still in production